X. Design Test Requirements
A. Life Testing:
1. ALT (Accelerated Life Testing)
a) A sample size of 30 units must be subjected to the
following test conditions for a total of 5 weeks:
(1) 5ºC / R.H.40% +/- 5% for 1 hour
(2) Ramp/transition to 85ºC / R.H. 90% for 1 hour
(3) 85 ºC / R.H. 90% +/- 5% for 10 hours
(4) Ramp/transition to 5 ºC / R.H. 40% for 1 hour
(5) Repeat steps until 5 week duration is complete.
2. HALT (Highly Accelerated Life Testing)
a) A sample size of 5 units each must be subjected to the
following tests:
(1) Cold Thermal Step Stress: -20
º
C (-4
º
F)
(2) Hold Thermal Step Stress: >+110
º
C (+230
º
F)
(3) Rapid Thermal Transition: 35 Grms (Gravity Root
Mean Squared)
(4) Vibration Step Stress: 45 Grms
(5) Combined Environment: 5 rapid temperature
cycles from -20
º
C to 110
º
C combined with vibration
ranging from 7 ~ 35Grms.
XI. Factory Test Requirements
According to R&D-20, section III.
XII. Warranty Period
One Year