Use and Care Manual

INSTALLATION
CONTROL PANEL
4
11
A
Position panel with plug connectors
facing down. Mount control panel
with fasteners, one in each corner
of the panel.
C
Connect the communication
cable to one of the comm terminals
and run down to user touchscreen
location.
D
Connect electrical plug to panel.
Twist connector to lock into place.
CAUTION: DO NOT CONNECT POWER
UNTIL MECHANICAL INSTALLATION
IS COMPLETE.
B
Connect VFD cable from fan to
control panel. Twist connector to
lock in place. Secure excess cable to
ceiling or beam.
NOTE
Twist Lock will act
as a disconnect.
TIP
For detailed
E-Stop (Fire Relay)
wiring, see Page 21
Before completing the mechanical installation, ensure breaker is off and all Lockout/Tagout procedures are
in place. The electrical receptacle for the panel should be installed prior to panel installation. For a chart of
receptacles, refer to page 19.
If the retention cable is not installed, the warranty will be voided.
WARNING!
A B
C
D
Do not use extension cord with fan
Do not remove covers while power is on
Do not use improper voltage source