User's Manual

19
TROUBLESHOOTING GUIDE
Problem Causes Solutions
Controller shows “ERR” in display
Module wires not properly
connected to controller terminal
Check the connection between module and controller and compare to
wiring diagram in System Installation section of Owner’s Manual
Solar Sync module shows “ERR”
Connection between module and
sensor faulty
Check connection between module and sensor (green and black wires)
Seasonal Adjust seems low
Region too high
Water Adjustment Setting too low
Location of Sensor does not allow
for full sun
Make sure controller dial is in “RUN” position. Increase the value on
the Water Adjustment scale (the default setting is 5). If you max out
the Water Adjustment scale at 10 and still require more seasonal
adjustment, move down one Region (from 4 to 3, for example) and start
at Water Adjustment setting 5. Solar Sync will immediately update the
Seasonal Adjust on the controller. If it is still too low, repeat the adjust-
ment until the desired seasonal adjust is showing on the controller.
Seasonal Adjust seems high
Region too low
Water Adjustment setting too high
Make sure controller dial is in “RUN” position. Decrease value of the
Water Adjustment setting. If you minimize the Water Adjustment scale
at 1 and still require a reduced seasonal adjustment, move down up
one Region (from 2 to 3, for example) and start at Water Adjustment
setting 5. Solar Sync will immediately update the Seasonal Adjust
on the controller. If it is still too high, repeat the adjustment until the
desired seasonal adjust is showing on the controller.
Rain or Freeze shutoff not activating
Rain Sensor Bypass Switch on
Controller set to “Bypass”
Jumper Clip still on controller
wiring terminal
Set the Controller Bypass Switch in the “Active” position.
Remove jumper clip.
Run times for a particular station are
too short/too long
Program Run Time too long/
too short
Solar Sync provides a global seasonal adjustment to the controller.
If a particular station has run times too long or too short, make the
appropriate adjustment to the program in the controller.
Solar Sync still sending Seasonal
Adjust when Controller Bypass
switch in the “Bypass” position
Solar Sync’s automated seasonal
adjustment cannot be de-activated
by the Bypass switch
The Bypass switch only controls the
Rain/Freeze shutoff function of the
Solar Sync
Hunter Technical Service: