Owner's Manual

WIRING DC LATCHING SOLENOIDS TO THE WVC ....................................
4
Leads are provided to attach a Hunter DC latching
solenoid or other two-wire, low-voltage latching solenoids
to the WVC. (Hunter DC latching solenoid part #458200)
Hunter DC latching solenoids have two leads: one colored
black and the other red.
To connect DC latching solenoids:
1. Select the appropriate station wire (red wire) on the
WVC Note: Station numbers are identified on top of
the WVC. Strip away " (13mm) of insulation from the
station wire.
2. Remove " (13mm) of insulation from the common
wire (black wire) on the WVC.
3. Twist the red and black
leads from the solenoid
to the red and black
leads on the WVC as
shown in the figure.
4. Make sure that waterproof connectors are used to
secure all wire connections.
NOTE: The maximum recommended
distance from the WVC to any Hunter DC
latching solenoid is approximately 100
feet with 18 gauge wire. Long distances
between the WVC and the DC latching sole-
noid will reduce overall 9-volt battery life.
NOTE: The black wire from each solenoid
must be wired to the single black lead on
the WVC controller.