Installation manual

44092-01 • 12/15/10 • Hunter Fan Company
10
7 Troubleshooting
Symptom Possible Causes Solution
1.No functions operate. Main Power not restored. Replace fuse. Turn ON circuit breaker. Turn ON wall switch.
Fan pull chain not set to High. Set fan pull chain to High speed.
Light pull chain not set to ON. Set light kit to ON.
Receiver wiring incorrect. Verify wiring connections.
Transmitter not programmed to
receiver in fan.
Re-program the remote. Refer to “Programming the Remote,” Page 8.
Battery too weak. Replace with new, 12-Volt alkaline battery. Refer to “Transmitter Installation”, Section 5.
2.Fan clicks when remote buttons
pushed, but blades do not move.
Fan pull chain not set to High. Set fan pull chain to High speed.
3.Fan clicks when remote buttons
pushed, but light does not work.
Light pull chain not set to ON. Pull light chain to turn ON.
4.Operates only at close range. Signal blocked from reaching
receiver.
Extend antenna into ceiling box, or move it for better reception.
Battery too weak. Replace with new, 12-Volt alkaline battery. Refer to “Transmitter Installation”, Section 5.
Interference Re-program the remote to a different frequency by pressing and holding fan speed
buttons 1 & 3 together for 5 seconds. Light on transmitter will blink 3 times. Light will
come on and fan will turn on at low speed to conrm programming is complete.
5.Inconsistent operation. Signal partially blocked from
reaching receiver.
Extend antenna into ceiling box, or move it for better reception.
RF interference. Turn OFF wall switch for 5 seconds, then turn back ON.
Continuing RF interference. Re-program the remote. Refer to “Programming the Remote,” Page 8.