I n s t a l l a t i o n G u i d e See page 2 ENGLISH Español Vea la página 23 Français Consulter la page 45 82048 Turino Bath Ventilator with Light READ and SAVE THESE INSTRUCTIONS 1 43042-01 02/21/2008
! W a r n i n g TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer. 2. B efore servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
Check all the parts. If damaged, call 1-888-830-1326 for replacements. * x4 A B * C x2 I Extra Screws 3/8” Cable Connector * NOTE: Strain relief cable connector must be installed. Not Included. 95044-01-000 E 95029-01-000 F 75191-01-000 G 03242-07-133 H 98037-01-000 I 74508-03-133 J 77521-01-000 K 65219-01-000 L 97959-01-000 M 75729-01-000 N 75184-01-133 O 97960-01-000 P 77535-01-000 ENGLISH x2 D Included. Tools Needed.
Before Installation NOTE: Remove all packing materials before installation. 2 1 I H Loosen screws. Turn off the power source. ENGLISH 3 4 H E Remove the motor/blower from the housing. Remove packing material. 5 6 Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing.
7 8 F G Remove the wiring cover screw. Remove the wiring cover. 9 10 ENGLISH E C B Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer.
New Construction – attaching to joist A12 A11 E 5/8 1/2 ENGLISH Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Screw pre-loaded screws into joist or framing. A13 Pull wires through the strain relief. A14 Ground Black Green White A 2 Pin Fan Motor F Bare Copper Black Main Switch 1 (AC In) White White Light 3 Pin Black Light *Option Black *Option Fan & Main Light Together Connect wires as shown.
A16 0 A15 E F G Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. A17 Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. 0 A18 ENGLISH 0 H Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing.
A21 A22 Go to step ON E1 on page 18 to attach grille. OFF Test the motor. If the motor does not run, check the plug connection. New Construction – suspended between joists B11 B12 ENGLISH E D 5/8 1/2 5/8 1/2 Slide the mounting rails into brackets. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. B14 B13 1/8" Bit E Mark position of screws by using holes as a template. Drill a hole in the center of each outline.
B16 B15 Insert screws, leaving space between the screw head and the joist. Screws are not provided. Attach the rails onto the screws. B18 B17 ENGLISH Tighten screws. Pull wires through the strain relief. B19 Ground Black Green White A 2 Pin Fan Motor F Bare Copper Black Main Switch 1 (AC In) White White Light 3 Pin Black Light *Option Black *Option Fan & Main Light Together Connect wires as shown.
B20 B21 F G Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. B22 ENGLISH B22 H H Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing.
B26 B27 ON Go to step E1 on page 18 to attach grille. OFF Test the motor. If the motor does not run, check the plug connection. Existing Construction – accessible from above C11 EXISTING FAN NO EXISTING FAN ENGLISH OR Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (8”x 8.5”). Use the motor housing as a template to mark position. C12 5” D 8. 8” E Cut out an opening for the housing. Slide the mounting rails into brackets.
C13 C14 5/8 1/2 5/8 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Mark position of screws by using holes as a template. C16 ENGLISH C15 1/8" Bit Drill a hole in the center of each outline. Insert screws, leaving space between the screw head and the joist. Screws are not provided. C18 C17 Attach the rails onto the screws. Tighten screws.
C19 C20 Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Pull wires through the strain relief. C21 ENGLISH Tighten the strain relief screws. C22 Ground Black Green White A 2 Pin Bare Copper Black Main Switch 1 (AC In) Fan Motor F White White Light 3 Pin Black Light *Option Black *Option Fan & Main Light Together Connect wires as shown.
C24 C23 H F G Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Connect wiring from motor the motor to the wiring cover plate. C25 ENGLISH C26 H I Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Secure the motor by tightening the 2 screws. C28 C27 ON OFF Turn on the power source. Test the motor.
C29 Go to step E1 on page 18 to attach grille. Existing Construction – accessible only from below D11 D12 EXISTING FAN ENGLISH E Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (8”x 8.5”). Move the housing into position above the ceiling. D13 1 2 D14 Pull wires through strain relief. 15 Attach existing ducting to duct connector. Tape joints. If ducting does not fit securely, an adapter may need to be purchased.
D15 E Install the housing flush with the sheetrock and secure by tightening the pre-loaded screws into the joist. ENGLISH D16 Ground Black Green White A 2 Pin Bare Copper Black Main Switch 1 (AC In) Fan Motor F White White Light 3 Pin Black Light *Option Black *Option Fan & Main Light Together Switch 2 (AC In) Connect wires as shown. D18 D17 F H G Connect wiring from the motor to the wiring cover plate. Install the wiring cover plate.
D19 D20 H I Secure the motor by tightening the 2 screws. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. D22 D21 ENGLISH ON OFF Turn on the power source. D23 Test the motor. If the motor does not run, check the plug connection. Go to step E1 on page 18 to attach grille.
E1 E2 L K Remove the thumbscrews. Connect wiring harness. E4 ENGLISH E3 J K Remove the strain relief bracket screw. Position the strain relief bracket under the motor as shown. E6 E5 Insert the strain relief bracket’s dog-leg tab so that it hooks over the lip of the motor. Reinstall the strain relief bracket screw. 18 Align posts A, B, C and D (stamped into motor housing) with posts A, B, C and D (stamped into light fixture). Slide light fixture over posts.
E8 E7 N Attach thumbscrews. WARNING: To reduce the risk of electrical shock, all 4 thumbscrews MUST be properly installed. Install 2 Max 60 Watt A15 bulbs (Not Included). E9 E10 ENGLISH O M Screw glass stop into position. Align glass dome and push up. E11 E12 P Complete.
Trouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker. • Check all plug connections to be sure they are secure. • Check the wiring to make sure it matches the wiring diagram. Problem: Light does not come on. Solution: • Replace the light bulb with a new bulb. • Turn power on, replace fuse, or reset breaker.
Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within one year afterthe date of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part free of charge for parts and labor performed at our nearest se