Owner’s Manual English Model 47124 5 MINUTE I N S T A L L A T I O N Non Programmable Form# 44115-01 20120806 ©2012 Hunter Fan Co.
Table of Contents Know Your Thermostat ������������������������������������������������������������������������������������������������� 3 Setting Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Alerts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Menu Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Know Your Thermostat Read this manual thoroughly. The following notes should help you with getting around your thermostat: • The thermostat temperature can be set in increments of 1°F (1°C). • After 15 minutes without a key press, the thermostat will return to the home display screen and save any changes you have made.
Know Your Thermostat 1. Allows access to the advanced features of the thermostat and saves changes to the menu options. 2. Adjusts time and temperature settings as well as moving up or down menu lists. 3. Indicates whether the system is set to Heat, Cool, or Off. 4. Indicates if the fan is set to Auto or On modes. 5. Allows you to switch between Heat, Cool, and Off modes. 6. Allows you to switch between fan Auto and On modes.
Know Your Thermostat 1 2 3 5 ©2012 Hunter Fan Company 4 6 5
Know Your Thermostat 1. Holds 2 “AA” Batteries. 2. HE/HG Switch - allows you to set your furnace to Gas/Oil or Electric, based on the type of system you have. 3. Allows your thermostat to operate your HVAC system* properly by indicating the system type that you have. *Conventional System: Uses a condensing unit for cooling and a separate furnace system for heating. *Heat Pump System: Uses the condensing unit for both heating and cooling.
Know Your Thermostat 1 2 3 ©2012 Hunter Fan Company 7
Know Your Thermostat 1. Indicates the current room temperature. 2. C will display when in Celsius mode. Nothing will display when set to Fahrenheit. 3. Low battery warning, replace the batteries in the thermostat. 4. Flashes when the furnace filter should be checked for replacement. 5. Indicates auxiliary heat on a heat pump is running. 6. Current operating mode, heat or cool. 7. Current Set temperature the thermostat is scheduled to run. 8. Indicates the fan is running when displayed. 9.
Know Your Thermostat o C 2 3 1 4 Filter 5 Aux Heat Cool to o 6 7 8 Auto 9 ©2012 Hunter Fan Company 9
Setting Temperature Once you install the batteries, the thermostat will display the home screen. 1. Set the system switch to Heat or Cool depending on your season. 2. Use the 3. Press the or or button to activate the thermostat. buttons again to adjust your set temperature. 4. Press when finished. The thermostat will show “Updated!” to confirm your settings are saved. NOTE: Follow this process anytime you need to make a change to your temperature.
Setting Temperature 2-3 1 O Heat to Auto 4 Updated! ©2012 Hunter Fan Company 11
Alerts This chapter will outline the various alerts the thermostat will report to you and how to respond to them. 1. Low Battery: This icon will appear when your batteries are starting to run low on power and should be changed to avoid system interruptions, (Figure 1) Change the batteries by gripping the sides of the thermostat firmly and pulling straight back, (Figure 1a). The batteries are located on the backside of the thermostat. The thermostat requires 2 (AA) batteries to operate.
Alerts 1a 1 O Heat to 1b 2 O Filter Heat to ©2012 Hunter Fan Company Auto 13
Alerts 3. Auxiliary Heat: On multi-stage heat pumps this alert indicates your second stage heat is running.
Alerts 3 O Aux.
Menu Options Under your menu options you have the ability to reset your filter counter, span settings, and temperature measurement. After making changes to each menu option, the thermostat will show “Updated!”, save your changes, and move you back to the home screen. To access these options: 1. Press the button. 2. Once in the menu options list, use the or buttons to scroll through the menu items. The button will take you into the selected menu item.
Menu Options 1 2 Filter Span 1 Span 2 F/ C O Filter Span 1 Span 2 F/ C O 3 O O 4 Filter Span 1 Span 2 F/ C O Span 1 O ©2012 Hunter Fan Company 17
Menu Options Example: If your thermostat is set to turn on at 72O in heat mode, with a span setting of 2, your thermostat will activate your furnace at 70Oand shut it down when it reaches 72O. For cooling at 72O with a span of 2, your air conditioner will activate at 74O and shut down at 71O. This setting can be changed to 1, 2, or 3. 1 will shorten your running time while 3 will lengthen it. 5.
Menu Options 5 6 Span 2 F/ C O ©2012 Hunter Fan Company O 19
Additional Features System Protection To protect your system from cycling, system turning on and off rapidly, your thermostat will prevent your system from turning back on for up to 3.5 minutes after it has been shut down. Reset In situations where your thermostat may not seem to be operating properly or if you just want to reset and start over, press and hold the and buttons for 3 seconds. This will restore the thermostat to factory condition.
Troubleshooting and Support Problem: No display. Solution: 1. Check battery position and battery life. Problem: Auto / Fan does not turn on. Solution: 1. Move HG/HE switch to opposite position. 2. Check the fan setting and make sure that it is not set to off. Problem: Fan runs continuously. Solution: 1. Check fan setting to see if it is set to on. 2. Move HG/HE switch to opposite position.
Troubleshooting and Support Problem: Heating or cooling does not turn on or off. Solution: 1. Check the system is in the right mode (heat or cool). 2. Be sure to wait up to 3.5 minutes for system protection if your system was just on. 3. Check breakers to make sure power is getting to your system. 4. Replace the batteries.
Technical Support If you need any assistance with installation or setup of your new Hunter thermostat, please call us. Our technical support staff is ready to help! USA: 1-888-830-1326 Canada: 1-866-268-1936 Hours of operation are from 7:00 am to 7:00 pm Monday - Friday and 8:00 am to 5:00 pm on Saturday, Central Time. You may also contact us over the Internet at www.HunterFan.com.
Limited Warranty Hunter Fan Company Thermostats LIMITED WARRANTY The Hunter Fan Company warrants your Hunter Thermostat to be free from defects in material or workmanship for a period of one year from the date of sale to the original user or consumer purchaser. If your Hunter Thermostat malfunctions or fails within the warranty period because of a defect in material or workmanship, we will replace it. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES.
Limited Warranty This warranty neither applies to batteries nor to deterioration of, nor damage to the product caused by the use of faulty batteries. Return your product, along with proof of purchase to Hunter Fan Company Service Department, 7130 Goodlett Farms Pkwy. Suite 400, Memphis, TN 38016. You will be responsible for all insurance and freight or other transportation charges to our factory. We will return your Hunter Thermostat freight prepaid.