BEFORE YOU BEGIN
PRE-INSTALLATION CHECKLIST
The location of the fan will alow for a minumum of 2 feet of blade clearance from
any obstruction and at least 10 feet of clearance above the oor.
If installing multiple fans, reference the fan placement chart for optimal spacing.
The control panel voltage markings (either 100-120VAC or 220-240VAC) should match
your building supply power.
Assess location
30 inches
from blade tip to
nearest wall or
obstruction
10 feet
from bottom
edge of blade
to the oor
Know your wiring
If you are unfamiliar
with wiring, use a
qualied electrician.
Must be able to
secure the fan to
building structure or
fan-rated outlet box
Select a downrod length
1
2
Standard Downrod
for ceilings 12-14 feet high
Longer Downrod
for ceilings 14 feet or higher
Assess ceiling angle
Maximum ceiling
angle is 34°.
!