41949-01 R20151220
W A R N I N G TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities. 1. Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer. 2. Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
Check all the parts. If damaged, call 1-888-880-3267 for replacements. E F G x5 A H I *B x2 J 3/8” Cable Connector * K C L x2 D Extra Screws M relief cable * NOTE: Strain connector must be N installed. Not Included. O 95044-01-000 95022-01-000 75190-01-000 03242-07-133 95492-04-000 74508-03-133 77520-01 65219 96373-01-214 75184-01-133 96374-01-214 Included. Tools Needed. (Not supplied.
3 4 I F Remove the motor/blower from the housing. Remove packing material. 5 6 Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. 8 7 G H Remove the wiring cover screw. Remove the wiring cover.
9 10 F C B Pop out the first wiring access slug. Use second if needed. Insert the strain relief (not Included) into the housing and secure with washer.
A13 Route wires through strain relief. For supply connection, use wires suitable for at least 90º C (194º F). A14 Ground Black Green 2 Pin A White Black Main Switch 1 (AC In) Fan Motor White White Night Light Light Bare Copper Red Night Light 3 Pin Black Light Red Switch 1 (AC In) *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. A16 0 A15 F H Install the wiring cover plate.
A17 0 A18 0 I Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. A19 A20 J Secure the motor by tightening the 2 screws. Turn on the power source. A21 A22 ON Go to step E1 OFF on page 17 to attach grill. Test the motor. If the motor does not run, check the plug connection.
New Construction – suspended between joists B12 B11 F E 5/8 1/2 5/8 1/2 Slide the mounting rails into brackets. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. B13 B14 1/8” bit F Mark position of screws by using holes as a template. Drill a hole in the center of each outline. B16 B15 Insert screws, leaving space between the screw head and the joist. Screws are not provided. Attach the rails onto the screws.
B17 B18 Tighten screws. Route wires through strain relief. For supply connection, use wires suitable for at least 90º C (194º F). B19 Ground Black Green 2 Pin A White Black Main Switch 1 (AC In) Fan Motor White White Night Light Light Bare Copper Red Night Light 3 Pin Black Light Red Switch 1 (AC In) *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. B20 B21 G H Install the wiring cover plate.
B22 B23 I I Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. B25 B24 J Secure the motor by tightening the 2 screws. Turn on the power source. B26 B27 ON Go to step E1 OFF on page 17 to attach grill. Test the motor. If the motor does not run, check the plug connection.
Existing Construction – accessible from above C11 EXISTING FAN NO EXISTING FAN OR Use the motor housing as a template to mark position. Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (9”x 9.75”). C12 F 9. 75 ” E 9” Cut out an opening for the housing. Slide the mounting rails into brackets. C14 C13 5/8 1/2 5/8 1/2 Mark position of screws by using holes as a template.
C15 C16 Drill a hole in the center of each outline. Insert screws, leaving space between the screw head and the joist. Screws are not provided. C18 C17 Attach the rails onto the screws. Tighten screws. C19 C20 Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Route wires through strain relief. For supply connection, use wires suitable for at least 90º C (194º F).
C21 Tighten the strain relief screws. C22 Ground Black Green 2 Pin A White Black Main Switch 1 (AC In) Fan Motor White White Night Light Light Bare Copper Red Night Light 3 Pin Black Light Red Switch 1 (AC In) *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. C23 C24 G I H Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Connect wiring harness.
C26 C25 J I Secure the motor by tightening the 2 screws. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. C27 C28 ON OFF Test the motor. If the motor does not run, check the plug connection. Turn on the power source. C29 Go to step E1 on page 17 to attach grill.
Existing Construction – accessible only from below D11 D12 EXISTING FAN F Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (9”x 9.75”). Move the housing into position above the ceiling D13 1 2 D14 Route wires through strain relief. For supply connection, use wires suitable for at least 90º C (194º F). Attach existing ducting to duct connector. Tape joints. If ducting does not fit securely, an adapter may need to be purchased.
D16 Ground Black Green 2 Pin A White Bare Copper Black Main Switch 1 (AC In) Fan Motor White White Night Light Red Night Light 3 Pin Light Black Light Red Switch 1 (AC In) *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. D17 D18 G I + Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS.
D22 D21 ON OFF Turn on the power source. D23 Test the motor. If the motor does not run, check the plug connection. Go to step E1 on page 17 to attach grill. Attaching the Grill E2 E1 F N M Remove the thumbscrews. Connect wiring harness. DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS.
E4 E3 K M Position the strain relief bracket between the plugs as shown, and screw into place. Align posts A, B, C and D (stamped into motor housing) with posts A, B, C and D (stamped into light fixture). Slide light fixture over posts. E6 E5 N Attach thumbscrews. WARNING: To reduce the risk of electrical shock, all 4 thumbscrews MUST be properly installed. Install 2 Max 60 watt A-15 bulbs (Not Included).
Complete. Troubleshooting Problem: Fan does not come on. Solution: the air movement. Problem: Light does not come on. Solution: Problem: Fan is noisy. Solution: If you have any additional questions or problems with your Hunter bath exhaust fan, please call: USA: 1-888-880-3267 We open 24 hours a day, 7 days a week. You may also reach us online at www.HunterHomeComfort.com. An electronic copy of this user manual can also be obtained online at www.HunterHomeComfort.com.
Warranty Hunter Home Comfort Bath Exhaust Fan LIMITED WARRANTY Hunter Home Comfort makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part free of charge for parts and labor performed at our nearest service center or at our Service Department in Marietta, Georgia.
41949-02 R20151220
A D V E R T E N C I A PARA REDUCIR EL RIESGO DE INCENDIO, CHOQUE ELÉCTRICO O LESIONES A PERSONAS, OBSERVE LO SIGUIENTE : 1. Utilice esta unidad sólo de la manera indicada por el fabricante. Si tiene alguna pregunta, contacte con el fabricante. 2. Antes de dar servicio o limpiar la unidad, desconecte la alimentación en el tablero de servicio y bloquee los elementos 5. 6. ser conectada accidentalmente. Cuando los elementos de una forma destacada de advertencia, como una etiqueta, en el tablero de servicio.
E componentes. Si están dañados, llame al 1-888-880-3267 para obtener un reemplazo. F G x5 A H I *B x2 J Conector de cable de 3/8” * K C L x2 D Tornillos adicionales M estar instalado * NOTA : Debe el manguito de alivio N de tensión del cable. No incluido. O 95044-01-000 95022-01-000 75190-01-000 03242-07-133 95492-04-000 74508-03-133 77520-01 65219 96373-01-214 75184-01-133 96374-01-214 Incluido.
3 4 I F Retire el motor/soplador del alojamiento. Retire el material de embalaje. 5 6 Retire las cubiertas de las puntas de tornillo precargadas. nivel con el lado del alojamiento. 7 8 G H Retire el tornillo de la cubierta del cableado. Retire la cubierta del cableado.
9 10 F C B Retire el primer tapón metálico de acceso del cableado. Utilice el segundo si es necesario.
A13 tension. Para conexiones de alimentación, use alambres adecuados al menos para 90º C (194º F). A14 Tierra Negro Verde 22 pasadores clavijas A Blanco Negro Interruptor principal 1 (CA) Motor del ventilador Luz de noche Luz Cobre desnudo Blanco Blanco Rojo Luz de noche 33 clavijas pasadores Negro Luz Rojo Interruptor 1 (CA) *Opción Negro Interruptor 2 (CA) *Opción ventilador y luz principal juntos Conecte los alambres como se muestra.
A17 0 A18 0 I Conecte el mazo de cables. NO PERMITA QUE EL MOTOR CUELGUE DEL MAZO DE CABLES. Vuelva a instalar el motor introduciendo las pestañas y A19 A20 J Asegure el motor apretando los 2 tornillos. Encienda la fuente de alimentación. A21 A22 ENCEN DIDO Vaya al paso E1 en la página 37 para fijar la rejilla. APAGA DO conexión del enchufe.
Construcción nueva – suspendido entre vigas B12 B11 F E 5/8 1/2 5/8 1/2 Deslice los rieles de montaje en los soportes. inferior de la viga, según el espesor de su plancha de yeso. B13 B14 broca de 1/8 de pulg. F Taladre un agujero en el centro de cada perfil. como una plantilla. B16 B15 Introduzca los tornillos, dejando espacio entre la cabeza del tornillo y la viga. No se proporcionan los tornillos. Fije los rieles con los tornillos.
B18 B17 Apriete los tornillos. tension. Para conexiones de alimentación, use alambres adecuados al menos para 90º C (194º F). B19 Tierra Negro Verde 22 pasadores clavijas A Blanco Motor del ventilador Luz de noche Luz Blanco Blanco 33 pasadores clavijas Cobre desnudo Negro Interruptor principal 1 (CA) Rojo Luz de noche Negro Luz Rojo Interruptor 1 (CA) *Opción Negro Interruptor 2 (CA) *Opción ventilador y luz principal juntos Conecte los alambres como se muestra.
B22 B23 I I Conecte el mazo de cables. NO PERMITA QUE EL MOTOR CUELGUE DEL MAZO DE CABLES. Vuelva a instalar el motor introduciendo las pestañas y B25 B24 J Asegure el motor apretando los 2 tornillos. Encienda la fuente de alimentación. B26 B27 Vaya al paso ENCEN DIDO E1 en la página 37 para fijar la rejilla. APAGA DO conexión del enchufe.
Construcción existente – accesible desde arriba C11 VENTILADOR EXISTENTE SIN VENTILADOR EXISTENTE O Utilice el alojamiento del motor como una plantilla para marcar la posición. sea suficientemente grande para acomodar el alojamiento del motor nuevo (9” x 9.75”). C12 F 9. 75 ” E 9” Recorte una abertura para el alojamiento. Deslice los rieles de montaje en los soportes. C14 C13 5/8 1/2 5/8 1/2 de la viga, según el espesor de su plancha de yeso. como una plantilla.
C15 C16 Taladre un agujero en el centro de cada perfil. Introduzca los tornillos, dejando espacio entre la cabeza del tornillo y la viga. No se proporcionan los tornillos. C18 C17 Fije los rieles con los tornillos. Apriete los tornillos. C19 C20 cinta a las uniones. Si el ducto no se ajusta firmemente, puede ser necesario comprar un adaptador. 32 tension. Para conexiones de alimentación, use alambres adecuados al menos para 90º C (194º F).
C21 Apriete los tornillos del aliviador de tensiones. C22 Tierra Negro Verde 22 pasadores clavijas A Blanco Negro Interruptor principal 1 (CA) Motor del ventilador Luz de noche Luz Cobre desnudo Blanco Blanco 33 pasadores clavijas Rojo Luz de noche Negro Luz Rojo Interruptor 1 (CA) *Opción Negro Interruptor 2 (CA) *Opción ventilador y luz principal juntos Conecte los alambres como se muestra. C23 C24 G I H Conecte el mazo de cables. NO PERMITA QUE EL MOTOR CUELGUE DEL MAZO DE CABLES.
C26 C25 J I Vuelva a instalar el motor introduciendo las pestañas y Asegure el motor apretando los 2 tornillos. C27 C28 ENCEN DIDO APAGA DO Encienda la fuente de alimentación. conexión del enchufe. C29 Vaya al paso E1 en la página 37 para fijar la rejilla.
Construcción existente – accesible sólo desde abajo D11 D12 VENTILADOR EXISTENTE F Mueva el alojamiento a su posición encima del techo. sea suficientemente grande para acomodar el alojamiento del motor nuevo (9” x 9.75”). D13 1 2 D14 tension. Para conexiones de alimentación, use alambres adecuados al menos para 90º C (194º F). cinta a las uniones. Si el ducto no se ajusta firmemente, puede ser necesario comprar un adaptador.
D16 Tierra Negro Verde 22 pasadores clavijas A Blanco Cobre desnudo Negro Interruptor principal 1 (CA) Motor del ventilador Luz de noche Luz Blanco Blanco 33 pasadores clavijas Rojo Luz de noche Negro Luz Rojo Interruptor 1 (CA) *Opción Negro Interruptor 2 (CA) *Opción ventilador y luz principal juntos Conecte los alambres como se muestra. D17 D18 G I + Conecte el mazo de cables. NO PERMITA QUE EL MOTOR CUELGUE DEL MAZO DE CABLES. debajo de la placa de cubierta del cableado.
D22 D21 ENCEN DIDO APAGA DO Encienda la fuente de alimentación. conexión del enchufe. D23 Vaya al paso E1 en la página 37 para fijar la rejilla. Fijación de la rejilla E2 E1 F N M Retire los tornillos de mano. 37 Conecte el mazo de cables. NO PERMITA QUE EL ARTEFACTO DE ILUMINACIÓN CUELGUE DEL MAZO DE CABLES.
E4 E3 K M Alinee los postes A, B, C y D (estampados en la caja del motor) con los postes A, B, C y D (estampados en el artefacto de iluminación). Deslice la lámpara sobre los postes. E6 E5 N Instale los tornillos de mano. ADVERTENCIA: Para reducir el Instale 2 bombillas A-15 de 60 vatios como máximo (No incluidas). instalarse apropiadamente. E7 E8 O Alinee las lengüetas del conjunto de la pantalla con las ranuras del dispositivo de iluminación e inserte las lengüetas en las ranuras.
Completo. Solución de problemas Problema : El ventilador no está operando. Solución : cerca de los conductos de ventilación para sentir el movimiento del aire. Problema : La luz no funciona. Solución : Problema : El ventilador hace ruido.
Garantía Hunter Home Comfort Extractor de aire para baño GARANTÍA LIMITADA Hunter Home Comfort establece la siguiente garantía limitada al usuario o comprador original de este Extractor de aire para baño Hunter : Si alguna pieza de su Extractor de aire para baño Hunter (con excepción de las lámparas de vidrio y las bombillas) falla en cualquier momento dentro de un año después de la fecha de compra debido a una falla de material o mano de obra, repararemos o, a nuestra elección, reemplazaremos la pieza defe