W A R N I N G TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities. 1. Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer. 2. Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
Check all the parts. If damaged, call 1-888-880-3267 for replacements. D E F x5 A G H *B x2 I 3/8” Cable Connector * J C K x2 I Extra Screws L relief cable * NOTE: Strain connector must be M installed. Not Included. N 95044-01-000 95022-01-000 75190-01-000 03242-07-133 95492-02-000 74508-03-133 77520-01 65219 95740-01/02-000 75184-01-133 95366-01/02-000 Included. Tools Needed.
3 H E Remove the motor/blower from the housing. Remove packing material. 5 6 Remove the pre-loaded screw tip covers. with the side of the housing. 7 8 G Remove the wiring cover screw. F Remove the wiring cover.
10 9 E C B Insert the strain relief into the housing and secure with the washer.
A13 Pull wires through the strain relief. A14 Ground Black Green 2 Pin A White Bare Copper Black Main Switch 1 (AC In) Fan Motor White White Night Light Red Night Light 3 Pin Light Black Light Red Switch 1 (AC In) *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. A15 A16 F 2 G 1 F Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Tighten the wiring cover plate screw.
A17 0 A18 H Connect wiring from the motor to the wiring cover plate. Connect 4” duct and vent to the outside. Tape joints. to be purchased. A19 A20 H I Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Secure the motor by tightening the 2 screws. A21 A22 ON OFF Turn on the power source. Test the motor. If the motor does not run, check the plug connection.
A23 Go to step E1 on page 18 to attach grille. New Construction – suspended between joists B12 B11 E D 5/8 1/2 5/8 1/2 Slide the mounting rails into brackets. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. B13 B14 1/8" Bit E Mark position of screws by using holes as a template. Drill a hole in the center of each outline.
B15 B16 Insert screws, leaving space between the screw head and the joist. Screws are not provided. Attach the rails onto the screws. B18 B17 Tighten screws. Pull wires through the strain relief. B19 Ground Black Green 2 Pin A White Fan Motor White White Night Light Light Bare Copper Black Main Switch 1 (AC In) Red Night Light 3 Pin Black Light Red Switch 1 (AC In) *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown.
B20 B21 F 2 G 1 F Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Tighten the wiring cover plate screw. B23 B22 H Connect wiring from the motor to the wiring cover plate. Connect 4” duct and vent to the outside. Tape joints. to be purchased. B24 B25 H I Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing.
B27 B26 ON OFF Turn on the power source. B28 Test the motor. If the motor does not run, check the plug connection. Go to step E1 on page 18 to attach grille. Existing Construction – accessible from above C11 NO EXISTING FAN EXISTING FAN OR Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (9”x 9.75”). Use the motor housing as a template to mark position.
C12 E 75 ” D 9. 9” Cut out an opening for the housing. Slide the mounting rails into brackets. C13 C14 5/8 1/2 5/8 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Mark position of screws by using holes as a template. C15 C16 1/8" Bit Drill a hole in the center of each outline. Insert screws, leaving space between the screw head and the joist. Screws are not provided.
C17 C18 Attach the rails onto the screws. Tighten screws. C20 C19 Connect 4” duct and vent to the outside. Tape joints. Pull wires through the strain relief. need to be purchased. C21 Tighten the strain relief screws.
C22 Ground Black Green 2 Pin A White Bare Copper Black Main Switch 1 (AC In) Fan Motor White White Night Light Red Night Light 3 Pin Light Black Light Red Switch 1 (AC In) *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. C23 C24 2 G 1 F Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Tighten the wiring cover plate screw.
C28 C27 I Secure the motor by tightening the 2 screws. Turn on the power source. C30 C29 ON Go to step E1 OFF on page 18 to attach grille. Test the motor. If the motor does not run, check the plug connection. Existing Construction – accessible only from below D11 D12 EXISTING FAN E Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (9”x 9.75”).
D13 1 2 D14 Attach existing ducting to duct connector. Tape joints. Pull wires through strain relief. an adapter may need to be purchased. D15 E Screw pre-loaded screws into joist or framing. D16 Ground Black Green 2 Pin A White Black Main Switch 1 (AC In) Fan Motor White White Night Light Light Bare Copper Red Night Light 3 Pin Black Light Red Switch 1 (AC In) *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown.
D18 D17 2 G 1 F Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Tighten the wiring cover plate screw. D20 D19 H H Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Connect wiring from the motor to the wiring cover plate. D21 D22 I Secure the motor by tightening the 2 screws. Turn on the power source.
D23 D24 Go to step ON E1 OFF on page 18 to attach grille. Test the motor. If the motor does not run, check the plug connection. Attaching the Grille E1 E2 H M N Remove the thumbscrews. Remove glass. E4 E3 H J L Position the strain relief bracket between the plugs as shown, and screw into place. Connect wiring harness. DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS.
E6 E5 L M Slide light mount over posts and attach thumbscrews. WARNING: To reduce the risk of electrical shock, all 4 thumbscrews MUST be properly installed. Install 2 Max 60 Watt A-15 bulbs (Not Included) and 1 Max 7 Watt C-7 bulb (Not Included). E7 N Align glass and push up. Trouble Shooting Problem: Fan does not come on. Solution: Problem: Fan is noisy. Solution: the vents to feel the air movement.
Warranty Hunter Home Comfort Bath Exhaust Fan LIMITED WARRANTY Hunter Home Comfort makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: date of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part free of charge for parts and labor performed at our nearest service center or at our Service Department in Marietta, Georgia.
20131201
A D V E R T E N C I A PARA REDUCIR EL RIESGO DE INCENDIO, CHOQUE ELÉCTRICO O LESIONES A PERSONAS, OBSERVE LO SIGUIENTE: 1. Utilice esta unidad sólo de la manera indicada por el fabricante. Si tiene alguna pregunta, contacte con el fabricante. 2. Antes de dar servicio o limpiar la unidad, desconecte la alimentación en el tablero de servicio y bloquee los elementos 5. 6. ser conectada accidentalmente. Cuando los elementos de una forma destacada de advertencia, como una etiqueta, en el tablero de servicio.
D componentes. Si están dañados, llame al 1-888-880-3267 para obtener un reemplazo. E F x5 A G H *B x2 I Conector de cable de 3/8” * J C K x2 I Tornillos adicionales L estar instalado * NOTA: Debe el manguito de alivio M de tensión del cable. No incluido. N 95044-01-000 95022-01-000 75190-01-000 03242-07-133 95492-02-000 74508-03-133 77520-01 65219 95740-01/02-000 75184-01-133 95366-01/02-000 Incluido.
4 3 H E Retire el motor/soplador del alojamiento. Retire el material de embalaje. 5 6 Retire las cubiertas de las puntas de tornillo precargadas. a nivel con el lado del alojamiento. 7 8 G Retire el tornillo de la cubierta del cableado. F Retire la cubierta del cableado.
10 9 E C B Retire el primer tapón metálico de acceso del cableado. Utilice el segundo si es necesario. firmemente con una arandela.
A13 A14 Tierra Negro Verde 22 pasadores clavijas A Blanco Cobre desnudo Negro Interruptor principal 1 (CA) Motor del ventilador Luz de noche Luz Blanco Blanco 33 pasadores clavijas Rojo Luz de noche Negro Luz Rojo Interruptor 1 (CA) *Opción Negro Interruptor 2 (CA) *Opción Ventilador y luz principal juntos Conecte los alambres como se muestra. A15 A16 F 2 G 1 F Apriete el tornillo de la placa de cubierta del cableado. caja o debajo de la placa de cubierta del cableado.
A17 0 A18 H Conecte el cableado del motor a la placa de cubierta del cableado. cinta a las uniones. Si el ducto no se ajusta firmemente, puede ser necesario comprar un adaptador. A19 A20 H I Vuelva a instalar el motor introduciendo las pestañas y Asegure el motor apretando los 2 tornillos. A21 A22 ENCEN DIDO APAGA DO Encienda la fuente de alimentación. la conexión del enchufe.
A23 Vaya al paso E1 en la página 38 para fijar la rejilla. Construcción nueva – suspendido entre vigas B12 B11 E D 5/8 1/2 5/8 1/2 Deslice los rieles de montaje en los soportes. de la viga, según el espesor de su plancha de yeso. B13 B14 broca de 1/8 de pulg. E Asegure el motor apretando los 2 tornillos. Taladre un agujero en el centro de cada perfil.
B15 B16 Introduzca los tornillos, dejando espacio entre la cabeza del tornillo y la viga. No se proporcionan los tornillos. Fije los rieles en los tornillos. B18 B17 de alivio de tensión. como una plantilla.
B20 B21 F 2 G 1 F Apriete el tornillo de la placa de cubierta del cableado. debajo de la placa de cubierta del cableado. B23 B22 H Conecte el cableado del motor a la placa de cubierta del cableado. cinta a las uniones. Si el ducto no se ajusta firmemente, puede ser necesario comprar un adaptador. B25 B24 B22 H I Asegure el motor apretando los 2 tornillos.
B27 B26 ENCEN DIDO APAGA DO Encienda la fuente de alimentación. B28 Pruebe el motor. Si el motor no funciona, Vaya al paso E1 en la página 38 para fijar la rejilla. Construcción existente – accesible desde arriba C11 SIN VENTILADOR EXISTENTE VENTILADOR EXISTENTE O sea suficientemente grande para acomodar el alojamiento del motor nuevo (9” x 9.75”). Utilice el alojamiento del motor como una plantilla para marcar la posición.
C12 E 75 ” D 9. 9” Recorte una abertura para el alojamiento. Deslice los rieles de montaje en los soportes. C13 C14 5/8 1/2 5/8 1/2 inferior de la viga, según el espesor de su plancha de yeso. agujeros como una plantilla. C15 C16 broca de 1/8 de pulg. Taladre un agujero en el centro de cada perfil. Introduzca los tornillos, dejando espacio entre la cabeza del tornillo y la viga. No se proporcionan los tornillos.
C18 C17 Fije los rieles en los tornillos. Apriete los tornillos. C19 C20 cinta a las uniones. Si el ducto no se ajusta firmemente, puede ser necesario comprar un adaptador. C21 Apriete los tornillos del aliviador de tensiones.
C22 Tierra Negro Verde 22 pasadores clavijas A Blanco Cobre desnudo Negro Interruptor principal 1 (CA) Motor del ventilador Luz de noche Luz Blanco Blanco Rojo Luz de noche 33 pasadores clavijas Negro Luz Rojo Interruptor 1 (CA) *Opción Negro Interruptor 2 (CA) *Opción Ventilador y luz principal juntos Conecte los alambres como se muestra. C23 C24 2 G 1 F Apriete el tornillo de la placa de cubierta del cableado. o debajo de la placa de cubierta del cableado.
C27 C28 I Asegure el motor apretando los 2 tornillos. Encienda la fuente de alimentación. C30 C29 ENCEN DIDO Vaya al paso E1 C27 en la página 38 para fijar la rejilla. APAGA DO la conexión del enchufe. I Construcción existente – accesible sólo desde abajo D11 D12 VENTILADOR EXISTENTE E Mueva el alojamiento a su posición encima del techo. sea suficientemente grande para acomodar el alojamiento del motor nuevo (9” x 9.75”).
D13 1 2 D14 Conecte el ducto existente con el conector de ducto. firmemente, puede ser necesario comprar un adaptador. D15 E Instale los tornillos precargados en la viga o el marco.
D18 D17 2 G 1 F Apriete el tornillo de la placa de cubierta del cableado. o debajo de la placa de cubierta del cableado. D20 D19 H H Conecte el cableado del motor a la placa de cubierta del cableado. Vuelva a instalar el motor introduciendo las pestañas y D21 D22 I Asegure el motor apretando los 2 tornillos. Encienda la fuente de alimentación.
D23 D24 ENCEN DIDO Vaya al paso E1 en la página 38 para fijar la rejilla. APAGA DO conexión del enchufe. Fijación de la rejilla E1 E2 H M N Retire los tornillos de mano. Retire la pantalla. E4 E3 H J L Conecte el mazo de cables. NO PERMITA QUE EL ARTEFACTO DE ILUMINACIÓN CUELGUE DEL MAZO DE CABLES.
E5 E6 L M Instale los tornillos de mano. Instale 2 bombillas A-15 de 60 vatios como máximo (No incluidas) y 1 bombilla C-7 de 7 vatios como máximo (No incluida). los 4 tornillos de mano DEBEN instalarse apropiadamente. E7 N Alinee la pantalla y levante. Solución de problemas Problema: El ventilador no está operando. Solución: Problema: El ventilador hace ruido. Solución: mano cerca de los conductos de ventilación para sentir el movimiento del aire. con libertad.
Garantía Hunter Home Comfort Extractor de aire para baño GARANTÍA LIMITADA Hunter Home Comfort establece la siguiente garantía limitada al usuario o comprador original de este Extractor de aire para baño Hunter: Si alguna pieza de su Extractor de aire para baño Hunter (con excepción de las lámparas de vidrio y las bombillas) falla en cualquier momento dentro de un año después de la fecha de compra debido a una falla de material o mano de obra, repararemos o, a nuestra elección, reemplazaremos la pieza defec