Operation Manual

40
VIEW VERSION AND STATION SIZE
Turn to Advanced Features dial position.
Press and hold the Information button.
This will display contact information for help. This
information is programmable at the Set Station and
Program Names dial position, if you wish to change it.
FP Temp is the internal facepack temperature. It is not used
and is informational only.
The Revision number is the version of ACC firmware loaded
in the controller. You can download the latest version of
firmware from www.hunterindustries.com and flash update
the controller facepack from a laptop computer.
Please note this version number whenever asking a
question from technical support about the ACC controller.
Station Size: Shows the number of station outputs
recognized by the facepack. This does not show how many
valves are in the field, or in use. It is the count of station
output modules (number of ACM600 or AGM600 modules x
6 stations each), or it will show 99” if an ADM99 Decoder
Output module is detected.
If station size is incorrect, or shows 0 or “1, check that
Powerlock slide is in the ON (locked) position. Check that
all station module contacts are in good order and that the
modules are fully inserted. Make sure powerlock tabs on
front of modules have good contact with the slide lock. An
incorrect station count may indicate a damaged module, if
it persists after all checks have been made.
When the info button is not pressed, the Advanced
Features may show all or some of the following items:
Utility Functions: ET Functions (only if ET Ready Master
Module and firmware are installed)
Event Mode Options: See Event Mode Options (agc,
surveyor) on page 75 for more information. (Golf only).
Decoder Functions (only if ADM99 decoder output module
is installed)
When viewing these menu selections, the left arrow button
on the facepack will operate as a Back button. Some
selections lead to another list of choices, and the Back
button will return you to the next highest level, without
having to turn the dial.
Select Utility Functions to see the following choices:
View Firmware Versions: Select to see version numbers of
all modules in use in the controller.
View Sensor Status: This will show the location and status
of the flow meter and all sensor inputs (1-4). CON means
Controller, or the screw terminals for sensor connections
inside the controller.