Operation Manual

51
START A CUSTOM MANUAL
Turn the dial to the Manual Operation position.
Use the Program button to select the Custom Manual
program (Custom Manual programs will appear after
the A through F selections).
Turn the dial to Run, to start the Program at the
beginning. The display will show “To Manually Start
Station 01…, but this only indicates that it will start
at the beginning of the program. Each station will run
for its programmed time, and stations with no run
time in the selected program will be skipped.
To start later in the Program (at a higher numbered
station), use the down arrow to move to the station
number, and press the +/- buttons to advance to the
desired station (or SSG) number.
Turn the dial back to Run to start the Program at the
desired station. The Program will begin at that station
and continue until the last event, then stop.
The display will show #-CUST under Mode, to show why
the stations are running.
TEST PROGRAM
Press and hold the Programs button
ACC has a quick Test program which will run all stations
for a selectable period of time, in numerical order. The Test
is an easy way to walk through every station in the system
to verify proper operation, or perform diagnostics. It also
features a quick advance for stepping through stations
with the arrow button.
Test does not run SSGs or programs. It activates each
individual station output in turn.
Run a Test Program
Turn the dial to the Run position.
Press and hold in the Programs button for
approximately 3 seconds.
The Test Program screen will appear below the time/
date display.
The screen will show Station 01 (and its name, if
applicable) and the run time field will be highlighted.
To start the Test Program on a station higher than 01,
use the Up and Down arrow buttons to advance the
starting station number.
Use the +/- buttons to set the test run time, in mm:ss
format. The maximum run time in Test mode is 15
minutes. The minimum run time for Test is one second
in conventional controllers and 15 seconds in decoder
controllers.
Use the right and left arrow buttons to move between
the minutes and seconds fields to set the universal
test time, and then wait a few seconds.
The Test program will begin running in 3 seconds if
no further buttons are pressed. Each station will show
the time remaining in the display.
Once the Test program is running, the stations can
be advanced or reversed without waiting for the run
times to complete. Press the right arrow button to
step up one station immediately. Press the left arrow
button to back up one station (this will restart the
previous station with a new Test run time).