HEPAtech ® Air Purification System Models 30378 & 30379 Replacement Filter Information Model Pre-Filter HEPAtech Filter 30378 30901 30931 30379 30901 30931 ® www.hunterfan.com 41773-01 04/15/2005 41773-01.
Table of Contents Safety Instructions .................................................................................................. 3 Introduction ............................................................................................................ 3 Description of Air Filtration System How the Air Purifier Works ............................................................................ 4 Air Purifier Components ................................................................................
SAFETY INSTRUCTIONS IMPORTANT! READ ALL INSTRUCTIONS BEFORE USING THIS AIR PURIFIER. 1. This air purifier is designed for use on a flat level floor and may not work properly on an uneven floor. ALWAYS place the air purifier on a firm level floor. ALWAYS place the air purifier at least six (6) inches away from walls and heat sources such as stoves, radiators, or heaters. 2. Place the air purifier in an area that is out of the reach of children. 3.
Description of Air Filtration System @; @; @; @; @; @; @; @; 41773-01 4
Description of Air Filtration System Display and Control Keys The display and control keys allow for easy operation of the air purifier. UP/DOWN KEYS: Adjusts the blower speed and turns the unit on and off. PRE-FILTER RESET: Resets the Carbon Pre-Filter Life Counter. FILTER RESET: Resets the HEPAtech® Filter Life Counter. IONIZER KEY: Turns the ionizer on and off. HEPAtech FILTER LIFE COUNTER ® Fig.
Operation Initial Operation This section provides basic instructions on the use of your air purifier. After following these initial directions, please continue reading this booklet to learn how to operate the more advanced features of your air purifier. Basic Operation of the Air Purifier: 1. Take the air purifier out of the box and remove the clear plastic protective bag. Place the unit on a firm level floor. 2.
Operation Filter Life Counters The pre-filter and filter are critical to the proper operation of the air purifier. To help you know when to change the filters, your Hunter Air Purifier has Filter Life Counters that will monitor the percentage of life your filter has left. Although the exact life of the filters depends on the environment, the table below gives typical usage times of the filters.
Operation Resetting the Air Purifier In the unusual situation that the unit or the display is exhibiting erratic behavior, you may want to reset the air purifier. If you still have problems after resetting the air purifier, please contact Hunter for additional assistance (refer to Technical Assistance, pg. 12). To Reset the Air Purifier: 1. Unplug the unit for at least 30 seconds. 2. Plug the unit back in. Using the Ionizer Using the ionizer improves the quality of air in the room.
Air Purifier Maintenance Cleaning Your Air Purifier Proper maintenance of your Hunter Air Purifier will help ensure years of trouble free service. Follow these steps to properly maintain your air purifier: 1. Approximately every 90 days, the outside of the unit should be cleaned with a soft, damp cloth. 2. If needed, the front grill can be removed from the unit and cleaned with soapy water. Simply remove the pre-filter before exposing the grill to water. 3.
Air Purifier Maintenance 6. Place the front grill back onto the unit. First, line up the tabs on the bottom of the grill with the openings on the purifier base and then push the top of the grill forward until it is closed. Refer to Figs. 2 and 3 (pg. 4). NOTE: This unit will not operate unless the grill is in the correct position. 7. Plug in the air purifier. 8. Finally, reset the Pre-Filter Counter by pressing the PRE-FILTER RESET key for 2 seconds.
Air Purifier Maintenance 6. Plug in the unit. 7. To reset the filter counter, press the FILTER RESET key for 2 seconds. The Filter Counter will return to 100% and the Filter indicator will stop flashing. Obtaining Replacement Filters To obtain replacement filters for your air purifier, first determine your model number by looking at the information label on the back of the air purifier. The model number will be listed on the label.
Troubleshooting Problem Solutions 1. No display or operation. • Confirm that the unit is plugged in. • Check the installation of the front grill. • Reset the air purifier. (See Resetting the Air Purifier on pg. 8.) 2. Keypad does not work. • Key pad has been locked to prevent accidental changes to the programs. (See Keypad Lock on pg. 7 to unlock the key pad.) 3. Erratic Display or Operation. • Reset the air purifier. (See Resetting the Air Purifier on pg. 8.) 4.
Warranty Hunter Fan Company HEPAtech® Air Purification System 5 YEAR LIMITED WARRANTY The Hunter Fan Company makes the following limited warranty to the original residential user or consumer purchaser of the HEPAtech® Air Purification System: If any part of your HEPAtech® Air Purification System motor or control panel fails during the first five (5) years from the date of installation due to a defect in material or workmanship, we will provide a replacement Air Purifier free of charge.
Warranty insurance and freight or other transportation to our factory service center. We will return the Air Purifier freight prepaid. The Air Purifier should be properly packaged to avoid damage in transit since we will not be responsible for any such damage. Proof of purchase is required when requesting warranty service. The purchaser must present sales receipt or other document that establishes proof of purchase.
Other Home Comfort Products from Hunter The Care-Free Humidifier ™ Programmable Thermostat To learn more about Hunter Fan Company products, please see our Web page at: www.hunterfan.