USE AND INSTALLATION INSTRUCTIONS INSTRUCCIONES DE USO E INSTALACION M odel/Modelo: HPAC-10C150-(A-Z) HPAC-12C150-(A-Z) HPAC-14C150-(A-Z) HPAC-14C150P-(A-Z) For questions about features, operation/performance, parts or service, call: (855) 887-1440 Para preguntas sobre las caracter f sticas, funci 6 n/rendimiento, piezas o servicio llame al: (855) 887-1440
TABLE OF CONTENTS IDENTIFICATION OF PARTS 2 AIR CONDITIONER SAFETY 3 INSTALLATION REQUIREMENTS 3 3 4 4 Tools and Parts Electrical Requirements Location Requirements INSTALLATION INSTRUCTIONS Unpack the Air Conditioner Install The Portable Air Conditioner Installation In Vertical Sliding Windows Installation In Horizontal Sliding Windows PORTABLE AIR CONDITIONER USE Starting Your Portable Air Conditioner Using the Remote Control Normal Sounds PORTABLE AIR CONDITIONER CARE Draining the Air Conditione
Front Cool air outlet Signal receptor Remote control Control panel Evaporator air intake Transport handle Secondary drain port Air outlet hose Condenser air intake Primary drain port Back 11 12 The figures in this manual are based on the external view of a standard model. They may differ from that of the air conditioner you have selected.
Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING". These words mean: A hazard that if not avoided will result in death or serious injury.
Electrical Requirements Wiring requirement WARNING 115 V (103.5 min. to 126.5 max.) 15 A time-delay fuse or circuit breaker Power Supply Cord A Electrical Shock Hazard B Plug into a grounded 3 prong outlet. Do not remove ground prong. RESET TEST Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. A. Test button B. Reset button NOTE: Your air conditioner’s device may differ from the one shown.
WARNING The length of the exhaust hose is specially designed according to the specification of the product. Do not replace, or extend , or otherwise modify the hose. Horizontal Sliding Window Vertical Sliding Window NOTE: ■ For best performance, allow at least 20 in of air space on all sides of the unit for good air circulation. ■ Do not block the air outlet. ■ Provide easy access to the grounded 3 prong outlet.
Install The Portable Air Conditioner Window Installation Install Exhaust Hose and Adapter Your window installation kit has been designed to fit most standard vertical and horizontal window applications. Roll the air conditioner to selected location. see "Location Requirements" in page 4. 1. Roll the air conditioner to selected location. see "Location Requirements" in page 4. 2.
Installation In Vertical Sliding Windows NOTE:The window installation kit can be used with vertical sliding windows between 18'' and 50'' wide. Foam seal J (Adhesive type-shorter) Foam seal I (Adhesive type -long) Cut the foam seal I(adhesive type-long) & J (adhesive type-shorter)to the proper length,and attcah it to the window sash and frame. Insert the vent panel assembly, including extension panels, if needed, into the window opening. Extend the extension panels to the window width.
Slot Insert Align the tabs on the window exhaust adapter with the slots in the vent panel. Insert the window exhaust adapter into the opening in the vent panel. Installation In Horizontal Sliding Windows NOTE: The window installation kit can be used with horizontal sliding windows between 18'' and 50'' wide.
Slot Insert 5 Align the tabs on the window exhaust adapter with the slots in the vent panel. Insert the window exhaust adapter into the Insert the window exhaust adapter into the opening in the vent panel. opening in the vent panel. PORTABLE AIR CONDITIONER USE Operating your portable air conditioner properly helps you to obtain the best possible results. This section explains proper air conditioner operation.
Power On or Off speeds Heating is NOT available for cooling only models.
Temperature Change display between °F and °C To change the temperature display between °F and °C press both the Plus and Minus Adjust buttons at the same time. ION (Optional) ■ ■ ■ NOTE: In the Cooling mode, the temperature can be set between 61°F and 86°F (16°C and 30°C). In Fan Only mode, the temperature can not be set. The unit LED shows the target temperature for 5 seconds and then displays the room temperature. Insert the Batteries 1. Remove the battery cover along the arrowed direction.
Remote control NOTE: Remote control may differ in appearance. Button and Function FAN SWING Indication symbols ON/OFF UP MODE DOWN DIMMER or Sleep FAN SWING TIMER Timer On/Off NOTE: Press and hold the MODE button on the remote for 5 seconds to switch the temperature display from degrees Fahrenheit(°F) to degrees Celsius(°C).
DIMMER Setting the Air Conditioner to Turn On: 1.Plug in the air conditioner and use the remote to power it ON. 2.Use the remote to set the desired mode, temperature, fan speed, etc. 3.Use the remote to power OFF the air conditioner. 4.Press TIMER on the remote and use the UP, DOWN buttons to set the desired delay time until the air conditioner turns ON. The delay time can be set from 0 to 24 hours in one-hour increments. 5.Press TIMER again to confirm the delay time. The TIMER light on the unit will be on.
WARNING: Please connect the drain hose on heating mode, or the unit will stop running after the water the water reaches warning level. Draining the Air Conditioner(non-Heating models) 1. Uncover the primary drain port. 2. Attach the drain hose to the primary drain hose. Make sure the connector has no water leak. 3. Place the other end of drain hose into a outfall. Check to see that the hose lies flat and is in the drain.
4. Remove the flexible exhaust hose and store with the air conditioner in a clean, dry area. See " installation Instructions ". 5. Remove the window kit and store with the air conditioner in a clean, dry area. See " Installation Instructions ". 6. Remove the filter and clean. See Cleaning the Air Filter. 7. Clean the outside of the air conditioner. See "Cleaning the Outside ". 8. Reinstall the filter. Before using the air conditioner again: 1. Make sure the filter and drain cap are in place. 2.
■ If the unit displays error code E5, the water container is full. Drain the water, see "Draining the air conditioner". After draining, the unit can be operated again. ■ If the unit display error code E1/E2/E3/E4/E6/E7/EA please contact customer service.
1 YEAR LIMITED WARRANTY Your appliance is covered by a limited one-year warranty and a limited 2-5 year warranty on the sealed system (the compressor, condenser, evaporator and tubing). For one year from your original date of purchase, Mindful, LLC will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used and maintained in accordance with the provided instructions.
Version No.