Programming Instructions Manual

ENG
2
A – LCD Display
1. Run Times Allows user to set each valve station run time
from 1 minute to 4 hours.
2.
Start Times Allows 1 to 4 start times to be set in each
program.
3. Station Number
Indicates currently selected station number.
4. Program Designator
Identifies program (A, B, or C) in use.
5. Day of the Week
Identifies day of the week
6. Interval Watering Identifies month when programming current date.
7. Odd/Even Watering
Identifies if Odd or Even watering has been
selected.
8. Flashing Sprinkler
Indicates that watering is taking place.
9.
System Off Allows user to discontinue all programs and
watering. Also allows the user to set the programmable “rain off
which stops watering for a period from 1 to 7 days.
10.
Umbrella Indicates that the rain sensor is active.
11.
Seasonal Adjustment Allows the user to make run time
changes according to the seasons without reprogramming the
controller. Bars on the left allow quick visual reference to the
seasonal adjustment percentage.
12.
Rain Drop Indicates watering will occur on the selected day.
13.
Crossed Rain Drop Indicates the watering will NOT occur on
the selected day.
14.
Calendar Indicates interval watering schedule has been
programmed. Icon also appears when programming the current day.
B – Wiring Compartment
15. Lithium Battery The replaceable lithium battery (included) allows
the controller to be programmed in the absence of AC power. In
addition, the battery will provide power for backup timekeeping in
the event of a power outage.
16. Internal Junction Box Junction box in outdoor models for
making AC power connections.
17. Terminal Strip – Use to attach transformer, sensor, and valve wires from
their source to the controller.
18. Reset Button Use to reset the controller.
C – Control Buttons
Button Increases the selected item flashing in the display.
Button Decreases the selected item flashing in the display.
Button Returns selected flashing display to previous item.
Button Advances the selected flashing display to the next item.
Button Selects program A, B or C for different watering zone
requirements.
19. Sensor Bypass Switch.
Dial Settings
Run Normal dial position for all controller automatic and manual
operation.
Current Time/Day Allows current day and clock time to be set.
Start Times Allows 1 to 4 start times to be set in each program.
Run Times Allows user to set each valve station run time from 1
minute to 4 hours.
Water Days Allows the user to select interval days to water.
Seasonal Adjustment Allows user to make run time changes ac-
cording to the seasons without reprogramming the controller. Bars
on the left allow quick visual reference to the seasonal adjustment
percentage.
1
Manual-One Station Allows user to activate a one-time watering
of a single valve.
ALL
Manual-All Stations Allows user to activate a one-time watering
of all valve stations or a few selected stations.
System Off Allows user to discontinue all programs and water-
ing. Also allows the user to set the programmable rain off which
stops watering for a period from 1 to 7 days.
D – External Transformer (Indoor Model only)
A plug in transformer is provided to supply AC power to the controller.