Use and Care Manual

9 HUSKYTOOLS.COM
Please contact 1-888-43-HUSKY for further assistance.
SPECIFICATIONS
PREPARING FOR INSTALLATION
Pre-Installation (continued)
Horsepower (HP) 3.7 Tank Outlet Size 3/4 in. NPT
Pump Type 2-Stage Oil Lubricated Oil Capacity Approximately 54 ounces
Voltage 230 / 240 Volts, 17.2 Amps
Depth 22 in.
60 Hz, 1 Phase
Width 27.5 in.
Air Delivery @ 175 psi 9.8 CFM Height 69.6 in.
Air Delivery @ 90 psi 10.4 CFM Shipping Weight 270 lbs
Air Delivery @ 40 psi 10.7 CFM
Max. Air Pressure 175 psi
Pump-up Time (0-175 psi) 11 Minutes
Recovery Time (145-175 psi) About 90 Seconds
A
18"
18"
18"
18"
A
CAUTION: Never use the shipping skid for mounting the
compressor.
IMPORTANT: Provide a minimum clearance of 18 in.
between the compressor flywheel or fan and the wall,
and ensure clear access to the drain valve to facilitate
condensate drainage.
IMPORTANT: It is extremely important to install the
compressor in a clean, well ventilated area where the
surrounding air temperature will not be more than 100 °F.
IMPORTANT: Do not locate the compressor air inlet near
steam, paint spray, sandblast areas, or any other source of
contamination.
IMPORTANT: This compressor is not intended for outdoor
installation.
Unbolt the air compressor unit (A) from the shipping skid.
Use a ratchet with a 1/2 in. socket.
Remove the air compressor unit (A) from the skid.
This requires at least two people - one person to “walk”
the unit off the skid and one to help maintain balance so
the unit does not topple. Place the air compressor unit (A)
where you plan to install it (at least 18in. from any wall
or surface).
WARNING: Disconnect, tag, and lock out power source,
and then release all pressure from the system before
attempting to install, service, relocate, or perform any
maintenance.
WARNING: This compressor is extremely top heavy. Enlist
additional help to remove it from the shipping skid.