To determine the correct manifold heater wattage, the available voltage supply must be specified. This practice is
necessary since a significant wattage reduction can occur if the lower voltage is not compensated for. For a given heater
the power output at 208V is only 75% of that at 240V.
Amperage Limitations
The amperage limit for each zone of the temperature controller needs to be identified. This ensures that the manifold
heaters will not exceed the amperage limit.
Electrical Connectors
Voltage Supply Wattage
240 V 2,880 W
208 V 2,160 W