Please confirm all dimensions and nozzle/gating suitability with Husky prior to machining.
Nozzle Selection Ultra 250
ULTRA 250 DESIGN INFORMATION
Ultra 250 Nozzle Pitch
Minimum nozzle pitch dimensions for the Ultra 250 nozzle are
provided on the right. For applications that exceed 16 drops, .
Nozzles can be grouped in maximum clusters of 8.
X and Y must be greater than 45.0mm (1.77”).
NOTE:
The sprue minimum radius 31.8 mm (1.25") and the X
and
Y minimum distances must all be satisfied.
NOTE: Minimum distance between outermost nozzle drop
center to outer edge of the manifold plate is 125mm (4.921”). If
reduced distance is required, contact Husky.
R 31.8