Use and Care Manual
6 | DOC-585_EN REV05 ORIGINAL INSTRUCTIONS
6. LOW VOLTAGE WIRE CONNECTION
1. 2. 3.
Fig. 4 Low voltage wire connection
Before connecting the low-voltage wires, make sure that the power unit is disconnected from
the electrical outlet�
1� First, strip the low voltage wires approximately 3/8 in / 10 mm;
2� Crimp the connectors onto the wires in order to hook-up the system�
3� Insert the low-voltage wires into the power unit’s low voltage terminal� Slightly pull on
the low-voltage wires to verify that they are properly fastened to the terminal�
4� To remove the wires, gently pull the connector out of the socket�
7. SYSTEM OPERATING INSTRUCTIONS
You may vacuum a great variety of materials with your new system, wet or dry� Before each
use, you must check that the ltration system in the canister is set up for the type of material
you are planning to vacuum�
dry materials
The permanent lter must be installed for this type of material� To optimize the ltering
capacities of your system, the use of an optional ltration bag is recommended�
Fine dust, sludGy materials, etc.
The permanent lter must be installed for this type of material� Pull a paper protection lter
(sold separately) over the permanent lter�
liquids and damp materials
Take o the permanent lter and all paper lters and bags while vacuuming liquids�
Now your new system is ready to be used, here are some simple guidelines to follow when
using your power unit:
• Insert the exible hose in one of the wall or oor vacuum inlets installed in your home;
• If you use a hose tted with a switch on the handle, use the interrupter on the hose’s
handle to turn the power unit on/o�
5. FLEXIBLE HOSE WITH ERGONOMIC HANDLE
At Husky, we understand that your cleaning
experience with a central vacuum system begins
above all with the use of the exible hose and
accessories� This is why we oer products above
market standards, on top of having
incomparable advantages like the best warranty
in the industry�
Fig. 3 Low voltage technology exible hose
Your Husky exible hose comes with a uniquely designed ergonomic handle, which makes its
use pleasant and worry free�
In your Husky hose handle, you will nd the same quality, durability and solid design made
with rst-quality materials� The top-of-the-line nish of your Husky exible hose is perfectly
harmonized with a series of accessories chosen by Husky to make a perfect cleaning kit� The
performance, simplicity and durability are the three principles which led to the development
of your Husky accessory kit� We are convinced that your cleaning experience will be improved
by it�
The purpose of a muer is to reduce the sound
emitted by the system� To install the muer on
your power unit, follow these simple steps:
1� Turn o and unplug the unit;
2� Attach the 90° long metal elbow upwards
or downwards onto the central vacuum outlet
(silicone coupler);
3� Secure the muer onto the 90° long
metal elbow using the provided self-tapping
screw;
Fig. 2 Installing the muer
4� OPTIONAL - If you plan on exhausting the central vacuum outside, install more metal
piping starting from the other end of the muer�
NOTE
» The muer can be oriented in the direction of the exterior vent. The
90° elbow is not mandatory.
» In case of space restriction around the power unit install the muer
at any convenient distance screwing spare metal piping in place.
IMPORTANT
DO NOT use any plastic piping (e.g. PVC) along the full length of the central
vacuumexhaust piping.
MUFFLER