Operators Manual

Table Of Contents
LED display Possible faults Possible action
Warning indicator flashing. Chain brake engaged. Pull back the front hand guard to re-
lease the chain brake.
Temperature deviation. Allow the product to cool down.
Overload. Cutting attachment jam-
med.
The cutting attachment is jammed.
Release the cutting attachment.
The power trigger and the activate
button are pressed at the same time.
Release the power trigger and the
product is active.
Green activate LED flashing. Low battery voltage. Charge the battery.
Warning indicator lit. Service. Turn to your servicing dealer.
Table 2: Battery
Troubleshooting the battery and/or the battery charger during charging.
LED display
Possible faults Possible action
Warning indicator flashing. The battery is discharged. Charge the battery.
Temperature deviation. Use the battery in surroundings
where tempereatures are between
-10 °C/14°F and 40°C/104°F.
Over voltage. Check that the mains voltage corre-
sponds with that stated on the rating
plate on the product.
Remove the battery from the battery
charger.
Warning indicator lit. Cell difference is too much (1V). Turn to your servicing dealer.
Table 3: Battery charger
LED display
Possible faults Possible action
Warning indicator flashing. Temperature deviation. Use the battery in surroundings
where temperatures are between
5°C/41°F and 40°C/104°F.
Warning indicator lit. Turn to your servicing dealer.
Transportation, storage and disposal
Transportation and storage
The supplied Li-ion batteries obey the Dangerous
Goods Legislation requirements.
Obey the special requirement on package and labels
for commercial transportation, including by third
parties and forwarding agents.
24 1259 - 001 - 11.07.2019