recommended to make an eyelet where the guide
wire will be connected. Make the eyelet with
approximately 20 cm / 8 in. of the boundary wire.
Note: Make a blueprint of the work area before
you install the boundary wire and guide wire.
D
E
B
C
F
A
Put the boundary wire around all of the work
area (A). Adapt the distance between the
boundary wire and obstacles.
Put the boundary wire 35 cm / 14 in. (B)
from an obstacle that is more than 5 cm / 2
in. high.
35 cm /14
"
> 5 cm / 2
"
Put the boundary wire 30 cm / 12 in. (C)
from an obstacle that is 1-5 cm / 0.4-2 in.
high.
1-5 cm / 0.4 - 2"
30 cm / 12"
Put the boundary wire 10 cm / 4 in. (D) from
an obstacle that is less than 1 cm / 0.4 in.
high.
10 cm / 4"
max 1 cm / 0.4"
If you have a paving stone path that is in
level with the lawn, put the boundary wire
below the paving stone.
Note:
If the paving stone is minimum 30 cm /
12 in. wide, use the factory setting for the
Drive Past Wire
function to cut all the grass
adjacent to the paving stone. Refer to
To set
the Drive Past Wire function on page 33
.
If you make an island, put the boundary wire
that runs to and from the island near
together (E). Put the wires in the same
stake. Refer to
To make an island on page
19
.
18
- Installation
1201 - 003 - 25.03.2020