436LiB, 536LiB, 530iBX EN Operator's manual 2-16
Contents Introduction..................................................................... 2 Troubleshooting............................................................ 12 Safety..............................................................................3 Transportation, storage and disposal........................... 13 Assembly........................................................................ 8 Technical data.............................................................. 14 Operation.........
15. Battery 16. Warning indicator (ERROR LED) 17. Battery indicator button 18. Battery status 19. Operator's manual 20. Harness (536LiB) 21. Harness, hip pad (530iBX) emission of the product is specified in the Technical data chapter and on the label. Product description The product agrees with the applicable EC directives. Symbols on the product or its packaging indicate that this product cannot be handled as domestic waste. This product must be deposited at an appropriate recycling facility.
Introduction WARNING: Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. General power tool safety warnings Check before starting • • • • • • • Inspect the working area. Remove all loose objects, such as stones, broken glass, nails, steel wire, string etc. that could be thrown out. Always remove the battery to prevent the machine being started by accident.
• and always use original accessories. Non-authorized modifications and/or accessories can result in serious personal injury or the death of the operator or others. Your warranty may not cover damage or liability caused by the use of non-authorized accessories or replacement parts. This product produces an electromagnetic field during operation. This field may under some circumstances interfere with active or passive medical implants.
• • • • • Watch out for thrown objects. Stones, rubbish, etc., can be thrown up into the eyes causing blindness or serious injury. Use a residual-current device (RCI) for increased security. A residual-current device is fitted to protect operators in case an electrical fault should occur. This product is renowned for its low vibration load. Overexposure to vibration can lead to circulatory damage or nerve damage in people who have impaired circulation.
retailer who sells your machine is not a servicing dealer, ask him for the address of your nearest service agent. • • • • To do a check of the keypad 1. Press and hold the start/stop button (B). B A C • • a) The product is switched on when the LED (A) is lit. b) The product is switched off when the LED (A) is out. 2. See Troubleshooting on page 12 if the warning indicator (C) is lit or flashes. • • • Battery charger safety To do a check of the power trigger 1.
• • Do not connect the battery charger terminals to metal objects as this can short circuit the battery charger. Use approved wall sockets that are not damaged. • • Safety instructions for maintenance WARNING: Read the warning instructions that follow before you do maintenance on the product. • • Remove the battery before you do maintenance, other checks or assemble the product. The operator must only do the maintenance and servicing shown in this operator's manual.
To connect the battery charger 2. Put the battery in the battery charger. 1. Connect the battery charger to the voltage and frequency specified on the rating plate. 2. Put the plug in a grounded socket outlet. The LED on the battery charger flashes green one time. 3. Make sure that the green charging light on the battery charger comes on. That means that the battery is connected correctly to the battery charger. Note: The battery will not charge if the battery temperature is more than 50 °C/122 °F.
2. Slide the battery into the battery holder of the product. The battery must slide easily, if not, it is not installed correctly. To start the product 1. Press and hold the start button until the green LED light comes on. 2. Use the power trigger to control the speed. 3. Press the lower part of the battery and push it in as far as it will go into the battery compartment. The battery will lock into position when you hear a click. 4. Make sure that the latches snap in place correctly.
3. Unplug the backpack battery cable from the product 3. Continue to work without needing to press the power trigger. 4. Press the cruise control button again to deactivate the cruise control function. . Note: If the backpack battery is not used for more than 30 minutes, the backpack battery turns off automatically. To start the backpack battery again, press the start button on the backpack battery. To set the optimal airflow for your work 1.
Maintenance Daily Make sure that the start/stop button works correctly and is not damaged. X Make sure the power trigger is functioning properly with regard to safety. X Check that nuts and screws are tight. X Check that the battery is intact. X Check the battery's charge. X Check that the release buttons on the battery works and locks the battery into the machine. X Check that the battery charger is intact and functional.
Keypad Possible faults Possible action Red error LED is lit The product needs servicing. Contact your servicing agent. LED display Possible faults Possible action Green LED flashing Low battery voltage. Charge the battery. Red error LED flashing The battery is discharged. Charge the battery. Temperature deviation. Use the battery in tempereatures between -10°C (14°F) and 40°C (104°F). Over voltage.
• Put the battery charger in storage where the temperature is between 5 °C (41 °F) and 45 °C (113 °F) and away from open sunlight. Charge the battery 30% to 50% before you put it in storage for long periods. Put the battery charger in storage in a space that is closed and dry. Keep the battery away from the battery charger during storage. Do not let children and other not approved persons to touch the equipment. Keep the equipment in a space that you can lock.
436LiB 536LiB 530iBX 0.7 0.5 0.4 Air flow in normal mode with standard nozzle, m3/min 11.0 11.6 12.1 Maximum air velocity in normal mode with standard nozzle, m/s / mph 47 / 105.1 48 / 107.4 49 / 109.6 Vibration levels5 Vibrations levels at handles, measured according to ISO 22867, m/s2 Fan performance Noise and vibration data are determined on the basis of the rated maximum speed. Approved batteries Only use original Husqvarna BLi batteries for this product.
EC Declaration of Conformity EC Declaration of conformity Husqvarna AB, SE-561 82 Huskvarna, Sweden, tel: tel: +46-36-146500, declares under sole responsibility that the battery leaf blowers Husqvarna 436LiB and 536LiB from 2018’s serial numbers and onwards (the year is clearly stated in plain text on the type plate with subsequent serial number), are in conformity with the requirements of the COUNCIL’S DIRECTIVES: • • • • • of May 17, 2006 ”relating to machinery” 2006/42/EC.
519 - 002 - 30.05.
519 - 002 - 30.05.
519 - 002 - 30.05.
www.husqvarna.