easier if an eyelet has been made on the boundary
wire as outlined in the previous description. See
Laying the boundary wire on page 18
.
8. Connect the guide wire to the boundary wire using a
coupler:
a) Insert the boundary wire and guide wire in the
coupler. Check that the wires are fully inserted
into the coupler so that the ends are visible
through the transparent area on the other side of
the coupler.
b) Use a polygrip to completely compress the
button on the coupler. It does not matter which
holes are used to connect each wire.
9. Staple down or bury the splice in the lawn.
CAUTION: The guide wire may not cross the
boundary wire, for instance a boundary wire that
is laid out to an island.
3.8 Checking the installation
Check the loop signal by inspecting the indicator lamp
on the charging station.
See
Indicator lamp in the charging station on page 52
if
the lamp does not indicate a solid or flashing green light.
3.9 First start-up and calibration
When the main switch is set to position
1
for the first
time, a start-up sequence in the robotic lawnmower’s
menu must be carried out as well as an automatic
calibration of the guide signal.
1. Open the hatch by pressing the STOP button.
2. Set the main switch to position
1
.
A start-up sequence begins when the robotic
lawnmower is started for the first time. The following
is requested:
Language.
Country
Date
Time
Selection and confirmation of personal PIN code.
All combinations except 0000 are permitted.
Note: Use the
MEMO
page at the beginning of the
manual to make a note of the PIN code.
3. Place the robotic lawnmower in the charging station
and press START. The robotic lawnmower will now
begin to calibrate the guide wire.
Press START and close the hatch. The calibration is
performed by the robotic lawnmower backing out of
the charging station and running a calibration
process in front of the charging station. When this is
completed, mowing can begin.
3.10 Test docking with the charging station
Before using the robotic lawnmower, check that the
robotic lawnmower can follow the guide wire all the way
to the charging station and easily docks with the
charging station.
The test function is found in the robotic lawnmower’s
Installation
>
Find charging station
>
Guide
>
More
>
Test guide
menu. For more information, see
Boundary >
More > Test right / Test left on page 29
.
If no guide wire is installed the test must be carried out
on the boundary wire, both clockwise and anti-
clockwise.
The guide system must first be calibrated if the above
test is to provide a satisfactory result.