Operation Manual

English - 19
3. INSTALLATION
The charging station must be positioned with a great
deal of free area in front of it (at least 10 ft
(3 metres)). It should also be positioned centrally in
the working area so that Automower
®
can easily find
the charging station and quickly reach all parts of the
working area.
It is a good idea to place the charging station in the
shadow. The battery is spared if it is charged in the
lowest possible ambient temperature.
The charging station must be positioned on relatively
level ground. The height difference must not differ
more than 2" (5 cm) between the front and rear of the
charging station.
The charging station must not be positioned so that
its plate bends.
Consider the distance to a wall socket when choosing
the position. The charging station should be
connected to a 120V (230V) wall socket via the low
voltage cable and transformer. The supplied low
voltage cable is 66 ft (20 metres) long.
Tip! It is possible to let the low voltage cable cross
the working area. It must then be either stapled down
or buried. In some cases there is a better positioning
option for the charging station than close to a house
wall or by the closest wall socket.
The transformer must be placed where it is well
ventilated and is not exposed to direct sunlight.
It is recommended to use an earth fault-breaker when
connecting the transformer to the wall socket.
IMPORTANT INFORMATION
The low voltage cable must not under any
circumstances be shortened or extended.
IMPORTANT INFORMATION
The power cord on the transformer must not
be replaced. In those cases where the power
cord has been damaged, the transformer
must be discarded and replaced by a new
one.