Operation Manual

32 - English
3. INSTALLATION
7. Refit the cover on the charging station. Ensure
the three guides on the charging station enter the
right holes in the cover.
3.6 Checking the installation
Check the loop signal by looking to see what
indication the green LED on the charging station is
giving.
Steady light = the signal is okay.
Flashing once every other second = break in the
loop and no signal found.
Flashing twice every other second = weak signal.
This may be due to the boundary wire exceeding
1600 ft (500 m) or that the cable is damaged. If
the mower works, it is not a problem. In case of
operational disturbance, we recommend a Signal
amplifier (522 42 58-01) which is available as an
accessory. This allows a boundary wire of up to
800 metres.
3.7 Linking Automower
®
to the
charging station
1. Open the control panel cover by pressing the
STOP button.
2. Place Automower
®
in the charging station.
3. Set the main switch to the ON position.
A start-up sequence begins when Automower
®
is
started for the first time. The following is
requested: Language, time format, correct time,
date format, date, and four-digit PIN code. All
combinations except 0000 are permitted.
When you have chosen a PIN code with Automower
®
placed in the charging station, the mower and
charging station are then linked to each other.
3.8 Installation of the guide wire
The guide wire is an extra wire that is laid from the
charging station, out towards a remote part of the
working area or through a narrow passage and is then
connected to the boundary wire. The same wire used
for the boundary wire is also used for the guide wire.
Up to two guide wires can be installed for Automower
®
265 ACX. In similarity to the boundary wire, the guide
wire can either be stapled down or buried.
ON
OFF