6. MENU FUNCTIONS
When the function is selected the mower will
immediately follow the boundary wire, guide 1 or
guide 2, depending on which one it finds first, in
to the charging station. If there is a passage and
the mower can not run through it, the Corridor
width value is set too high. When Test IN is
activated, the mower runs at the greatest
distance from the wire that the selected corridor
width permits.
The adjacent picture shows how Automower
®
negotiates a passage when a value of 8 is set for
the Corridor width, but not when a value of 10 is
set.
Test OUT (3-2-5)
The Test OUT (3-2-5) function is used to try
different charge exit settings and to find out how
far it is from the charging station to a remote
area.
To test the settings for Follow loop out (3-2-1):
State the value 100 % for Proportion for the
remote area to be tested and 0 % for the other
areas. Place Automower
®
in the charging
station and select Test OUT (3-2-5). The
mower will now leave the charging station
directly according to the stated direction and
start mowing after the stated distance. Reset
the Proportion values when testing is finished.
To find out the distance from the charging station
to a remote area:
State a distance that easily exceeds the true
distance. The maximum distance that can be
stated is 1600 ft (500 meters). State the value
100 % for Proportion for the area to which the
distance is to be measured and 0 % for the other
areas. Place Automower
®
in the charging station
and select Test OUT (3-2-5). The mower will
now leave the charging station directly according
to the stated direction. The distance will be
shown on the display, stated in meters, as the
mower runs. Stop the mower after the required
distance and read the distance. Enter the
number of metres shown in Distance for the area
in question. Reset the Proportion values when
testing is finished.
IMPORTANT INFORMATION
When Test IN (3-2-4) is used, the house icon
on the display will come on and the mower
will remain in the charging station. Press the
Home button to return to operations.
10
8
3-2-4
Follow loop out
Follow loop in
Corridor width
Test IN
Test OUT