7. GARDEN EXAMPLE - PROPOSED INSTALLATION
Area: 1.1 acre (4500m
2
). A number of islands
and a steep slope along the boundary wire.
Guide wire recommended.
Timer: Operating time of 24 hours per day.
Exit angles: 90° - 270°.
Search method: Irregular and Follow guide
wire in.
Delay: Guide1, 2 minutes, Guide2, 2 minutes
and boundary wire 99 minutes. Automower
®
is never permitted to follow the boundary
wire.
Corridor width: 19
Area: 0.4 acre (1600 m
2
). L-shaped garden
with the charging station placed in the large
open area. No guide wire is necessary.
Timer: Operating time of 8 hours per day.
Exit angles: 90° - 270°.
Search method: Irregular and Follow
boundary wire in.
Delay: Guide1, 2 minutes, Guide2, 2 minutes
and boundary wire 11 minutes.
Corridor width: 19
Area: 0.4 acre (1600 m
2
). L-shaped garden
with the charging station placed in the narrow
area. There are two islands. No guide wire is
necessary.
Timer: Operating time of 8 hours per day.
Exit angles: 250° - 290°
Search method: Irregular and Follow
boundary wire in.
Delay: Guide1, 2 minutes, Guide2, 2 minutes
and boundary wire 11 minutes.
Corridor width: 19
Proposals for installation and settings
16 ft