Test settings
Testing selected settings can be seen as a natural part of
the installation.
To test the selected settings:
1. Place the robotic lawnmower about 3 metres from
the wire to be tested (boundary wire or the guide
wire), facing the wire.
2. Use the right/left arrow key to select the method to
test from the Overview screen.
3. Select More and press OK.
4. Select Test Guide under Guide settings, or Test
right or Test left under boundary settings, and
press OK.
5. Press START and close the display hatch.
Check that the robotic lawnmower follows the
guide wire all the way to the charging station and
that it docks with the charging station. The test
is approved only if the robotic lawnmower is able
to follow the guide wire the entire distance to the
charging station and docks at the rst attempt.
If the robotic lawnmower is unable to dock on
the rst attempt, it will automatically try again.
The installation is not approved if the robotic
lawnmower needs two or more attempts to dock
with the charging station.
Normal causes as to why the robotic lawnmower
cannot follow the wire are that obstacles close
to the wire have not been isolated or that the
guide wire has not been laid at an angle on a
steep slope. Check that the charging station, the
boundary wire and the guide wire are installed in
accordance with the instructions in chapters 3.2,
3.4 and 3.6.
If manual settings are done, the wrong corridor
width may also have been selected.
6. The test is approved when the robotic lawnmower
can follow the selected wire to the charging
station and dock with it on the rst attempt without
any problems.
Using Test, the robotic lawnmower travels the
maximum distance from the wire dened by the
selected corridor width.
Reset
The specic settings for each method can be reset to factory
default. To reset, select the method using the left and right
arrow keys followed by OK. Select More, then Reset and
press OK.