3.5 Connecting the Boundary Wire
Connect the boundary wire to the charging station:
IMPORTANT INFORMATION
The boundary wire must not be crossed
when connecting to the charging station.
The right hand wire end must be connected
to the right hand pin on the charging station
and the left hand wire end to the left pin.
1. Place the cable ends in the connector:
Open the connector.
Place the wire in the connector grip.
2. Press together the connectors with a pair of
pliers. Press until you hear a click.
3. Cut off any surplus boundary wire. Cut 1-2 cm
above each connector.
4. Tilt the protective cover on the charging station
forward and run the wire ends up each channel
at the rear of the charging station. Press the
connector onto the contact pin, marked AL (left)
and AR (right), on the charging station.
5. Mark the wires with the accompanying wire
labels. This makes it easier to reconnect the wires
correctly when for instance the charging station
has been stored indoors for the winter.
IMPORTANT INFORMATION
The right hand connector must be con-
nected to the right hand contact pin on the
charging station and the left hand wire end
to the left connector.
1157866-26,420,430X,450X,EN_160314.indd 27 2016-03-14 16:58:42