Operation Manual

Max 5 cm/12"
Max 5 cm/12"
3012-1054
3012-1053
3023-038
3012-555
3012-1352
3018-069
English - 18
INSTALLATION
The charging station must be positioned with a great deal
of free space in front of it (at least 3 meters). It should
also be centrally placed in the working area to make it
easier for the robotic lawnmower to reach all areas in the
working area.



The charging station must be positioned on relatively
level ground. The front end of the charging station may
be a maximum of 5 cm higher or lower than the back end.
The charging station must not be positioned so that its
plate bends.
Connection of Power Supply
Take the following into consideration when planning
where to place the power supply:
 Close to the charging station
 Protection from rain
 Protection from direct sunlight
If the power supply is connected to an electrical socket
outdoors, it must be approved for outdoor use.
The low voltage cable for the power supply is 10 meters
long, and may not be shortened or extended. A longer low
voltage cable is available as optional accessory. Contact
your local dealer for more information.
It is not allowed to connect the power supply directly to
the charging station. The low voltage cable must always
be used.
1157866-26,420,430X,450X,EN_160314.indd 18 2016-03-18 08:19:39