Rev.
IGUP-RED-0309 General Instructions Table of Contents THIS BOOKLET CONTAINS INFORMATION ON: RED A narrow depth multi deck air curtain case designed to display pre-packaged Deli products. It can be placed at the end of gondolas or within a gondola by removing a gondola deck and shelves above from one 4'-0" section. General Instructions ................................................. 2 Cut & Plan Views ....................................................... 3 Installation ................................
Rev.0309 Cut & Plan Views 23 1/8" 40 1/8" 12" 58 1/2" 14" 18" 6 1/2" 14 1/4" 22 1/2" 33 1/2" 39" RED Refrigerated Self Sevice End Display Scale = 1/2" Elec. Drain 17" 9" 16" 39" 33 1/2" 14" 5" Ref.
IGUP-RED-0309 Installation store floor. B. When wedges are involved in a lineup, set them first. LOCATION The refrigerated merchandisers have been designed for use only in air conditioned stores where temperature and humidity are maintained at or below 75°F and 55% relative humidity. DO NOT allow air conditioning, electric fans, ovens, open doors or windows (etc.) to create air currents around the merchandiser, as this will impair its correct operation.
Rev.0309 Plumbing the floor drain and outlet of condensate drain. 1" is ideal. 6. Prevent condensate drains from freezing: a. Do not install condensate drains in contact with non-insulated suction lines. Suction lines should be insulated with a nonabsorbent insulation material such as Armstrong’s Armaflex. b. Where condensate drains are located in dead air spaces (between refrigerators or between a refrigerator and a wall), provide means to prevent freezing.
IGUP-RED-0309 Refrigeration REFRIGERANT TYPE The standard refrigerant will be R-22 unless otherwise specified on the customer order. Check the serial plate on the case for information. tronic expansion valves will be installed on the coil inlet, coil outlet, and in the discharge air. (Some supermarkets require a 4th sensor in the return air).
Rev.0309 T-STAT LOCATION START-UP SELF CONTAINED On self contained cases the unit is completely charged and tested to the porper temperature. Siwtch on the compressor. Set the timeclock to the proper time of day by turning the dial in the direction of the arrow until the pointer and current time of day align. The T-stats are located within the electrical raceway. The raceway location is dependent on the style of the front panel and whether the case is going to be pushed up against a wall. (See diagram.
IGUP-RED-0309 Case Specifications Model & Length 4' Refrigeration Btu / Hr. (Ft.) (Total) 1,700 6,800 6' 1,700 10,200 8' 1,700 13,600 12' 1,700 20,400 Average Disch. Air T~Stat Coil Fan Blade Temperatures (°F) Speed Settings Type Size (in) & Evap. Prod. Disch.
Hussmann Corporation, Int'l. 13770 Ramona Avenue Chino, CA. 91710 (909)-590-4910 Lic.#: 644406 N REVISIONS: #: DESCRIPTION: L BALLAST 125-01-3266 FULHAM LH3-120-L DATE: POWER: ~115 VAC - 50/60 Hz. - 3 WIRE BUNDLE COLOR ORANGE LIGHT SWITCH 125-01-0307 BALLAST 125-01-3266 FULHAM LH3-120-L SHELF & CANOPY LIGHTING (4) FP28T5/830 L N L T-STAT N BUNDLE COLOR BLACK & WHITE POWER: ~115 VAC - 50/60 Hz. - 3 WIRE MAIN CASE SUCTION SOLENOID DRAWN BY: D.
IGUP-RED-0309 User Information STOCKING CASE CLEANING Improper temperature and lighting will cause serious product loss. Discoloration, dehydration and spoilage can be controlled with proper use of the equipment and handling of product. Product temperature should always be maintained at a constant and proper temperature. This means that from the time the product is received, through storage, preparation and display, the temperature of the product must be controlled to maximize life of the product.
Rev.0309 ANTISTATIC COATINGS PLEXIGLASS & ACRYLIC CARE For acrylic used indoors, antistatic coatings successfully prevent the accumulation of an electrostatic charge for periods of several months—if the surface is not washed or wiped down with a wet cloth. Between applications of the antistatic coatings, the parts need only be dusted with a soft clean cloth to maintain a good appearance. In use, liquid antistatic coatings should be applied in a very thin even coat.
IGUP-RED-0309 Appendices normal refrigeration practices. Refrigeration piping should be insulated according to Hussmann’s recommendations. 1.3 A clogged waste outlet blocks refrigeration. The installer is responsible for the proper installation of the system which dispenses condensate waste through an air gap into the building indirect waste system. 1.
Rev.0309 1°C (1.8°F). Temperature measuring devices that are scaled only in Fahrenheit shall be accurate to 2°F. The thermometer should be checked for proper calibration. (It should read 32°F when the stem is immersed in an ice water bath). b) LOCATION – The probe or sensing element of the thermometer should be located in the airstream where the air first enters the display or storage area, and not more than 1 inch away from the surface and in the center of the discharge opening.
IGUP-RED-0309 14
Rev.0309 LIMITED WARRANTY This warranty is made to the original user at the original installation site and is not transferable. Hussmann merchandisers are warranted to be free from defect in material and workmanship under normal use and service for a period of one (1) year from the date of original installation (not to exceed fifteen (15) months from the date of shipment for the factory). Hussmann Impact Modular Coils are warranted for a total of five (5) years based upon the above criteria.
IGUP-RED-0309 Service Record Last service date: By: /Chino The MODEL NAME and SERIAL NUMBER is required in order to provide you with the correct parts and information for your particular unit. Additional copies of this publication may be obtained by contacting: Hussmann® Chino 13770 Ramona Avenue • Chino, California 91710 (909) 628-8942 FAX (909) 590-4910 (800) 395-9229 They can be found on a small metal plate on the unit. Please note them below for future reference.