User manual

IGHT-ESH/ESHS-0010
30
By:
Checked By:
No. Description:
Revisions:
W6000014
Hussmann Corporation
13770 Ramona Avenue
Chino, CA. 91710
(909)-590-4910
Lic.#: 644406
Date:
Drawing Title:
Next Assembly:
Drawn By:
Drawing No.:
Project Title:
Date:
Boris Kasrel
BK
01.25.2000
final
Sheet 1 of 1
ASH, ESH/S, RGSH-S/L, RGSHS
6' Combo, 3 Pan Well + 2' Griddle Service Counter
WH3-120-164
Ballast
POWER
#125-01-0311
LIGHT
#125-01-0311
S
L1
L2
L3
N
G
S
L
Remote
Sensing Bulb
Water Level Switch
Warrik Controller
Water Solenoid
Valve
24"x24" Griddle
570 W/~ 240V Flx Htr
L1
G
L2
H
L
NC
C
NO
L3
L2
L1
G
black
~208/240V-1Ø-
60
H
z
S
black
orange
black
Term Block
black
white
Toggle-Well Control
(Water Level Control)
6
4
21
5
P1
37
L
H1
L1
L2
H2
P
L
S
o
u
t
hr
e
n
W
ell
(3) w/Removable Pan
1200/1600W/~ 240V ea.
o/h HE-00-43"
1400W/~240V, wells
L
H1
L1
L2
H2
P
(2) F21T5/TL830
white
blue
Overhead Installation
Optional Left
~
1
1
5
V
/
5
A
m
p'
s
~
1
1
5
V
/
5
A
m
p'
s
Optional Right
Sensor
o
/
h
H
E
-
2
1
-
2
2
"
1
0
0
0
W
/
~
2
4
0
V
,
g
r
i
d
d
l
e
* #225-01-330
Snap-On T-Stat
20N11T002-L250
ON:183°F
OFF: 210°F
* T-Stats have to be installed at each end of the case
next to outer gas spring hinge to protect O-Ring from overheating.
orange
black
blue
T-Stat
Infinite
Controller
white
10AWG
10AWG
10AWG
40A
W
H
3
-
1
2
0
-
1
6
4
B
a
l
l
a
s
t
(
2
)
F
2
1
T
5
/
T
L
8
3
0
15A
FUSE
N
o
t
e
:
case must be grounded
208 V 240 V
L1
L2
L3
19.2
22.2
15.6
14.2
18.0
17.4
Loads, Amp