User Guide
IGSV-ASCS-0303
34
Light Switch
Overhead Canopy Lights
Front Lights
Ledge Lights
(Optional)
Ballasts
WH3-120-164 (125-04-0118)
Thermostat
Suction Solenoid
F32T8-SPX30 (1)
Duplex Receptacles
Humidity Fans
GFCI Dedicated
Line
Ballast Extension Box
(Switched Power)
Evaporator Fans
Cap
Case to Case Harness
Single case Pigtail
F32T8-SPX30 (2)
F32T8-SPX30 (2)
F32T8-SPX30 (2)
F32T8-SPX30 (2)
Plenum extension
Evaporator Fans
Plenum extension
Evaporator Fans
125-04-0107
125-04-0101
125-04-0108
125-04-0109
125-04-0110
125-04-0112
125-04-0111
125-04-0114
125-04-0113
125-04-0112
125-04-0112
125-04-0112
125-04-0113
125-04-0113
125-04-0112
125-04-0110
125-04-0100
125-04-0115
Heater Wire
(case rear)
Anti-sweat Fans
(Optional)
125-04-0121
125-04-0115
Tubular Heater Element
(Front air sweep heater)
(Optional)
125-04-0115
475-01-1421
(2) Anti-sweat Heat Rope 12' approx
Parallel Run on Front extrusion
125-04-0119
125-04-0109
125-04-0122
125-04-0123
Heater switch
(optional)
Sheet of
final
Date:
Project Title:
Drawing No.:
Drawn By:
Next Assembly:
Drawing Title:
Date:
Hussmann Corporation
13770 Ramona Avenue
Chino, CA. 91710
(909)-590-4910
Lic.#: 644406
Revisions:
No. Description:
Checked By:
By:
12' Case with T8 Lights
W0100005.dft
1
ASC-UPP Universal Power Module
Adrian Crisci
05.02.2000
1 Added air sweep heater
switch and harnesses
07/23/99 AEC
1
2 Updated front anti-sweat heater rope wire 05.24.00 BK