Operation Manual

12
CHANGES AND TYPING ERRORS RESERVED CHANGES AND TYPING ERRORS RESERVED
Additional safety rules
Always keep in mind that:
the machine must be switched off and disconnected from the power supply during maintenance and repairs,
clamped workpieces may only be measured when the machine is switched off.
Never lean over the machine, mind loose clothing, ties, jewellery etc. and wear a cap.
Do not remove safety devices or guards. Never use the machine while a guard is open.
Always use safety glasses for machining rough materials.
Burrs and chips should only be removed using a sweeper or other aid, never with your bare hands!
Never leave the machine running unattended.
Always wear safety glasses.
2. aTTenTion
Please read the operation manual carefully before the installation and adjustment of the machine. When the
installation is finished, check all components and perform an idle trial run before putting the machine into
operation. In case of problems, please contact your Huvema dealer.
Make sure you read all the safety instructions and follow them carefully.
3. machine appearance, applicaTions and work environmenT
3.1. machine appearance
The machine design encompasses the gear box, spindle box, column, work table, bracket, base and electrical
cabinet. The gear box is atop the spindle box. The spindle box is mounted on top of the column. The work table is
supported by the bracket, which is assembled in the middle of the column. The column sits on the base.
Figure A – Outline drawing
A1 - Electrical cabinet A5 - Lifting system
A2 - Gear box A6 - Work table
A3 - Spindle box A7 - Bracket
A4 - Column A8 - Base
3.2. applicaTions
This machine is designed for drilling, broaching, reaming, tapping, boring and similar operations. The large
drilling capacity allows for drilling of workpieces within a large size range. The machine is suitable for production
and maintenance shops.
The worktable bracket can move up and down along the column at 180°, or 45° parallel to the bracket. This
design is very flexible and easy to operate.
3.3. work environmenT
The elevation of the workshop must be 2000 m or less.
The environmental temperature should be 20° C to 40 ° C.
With a medium temperature of 20 ± 5° C, the relative humidity should not exceed 85 %.
No conductive dust allowed.
Installation in an environment with explosion danger is forbidden.
No corrosive gas or steam which may corrode metal or damage the insulation.
Keep away from the source of shocks or vibration.