Operation Manual

29
not brittle. Failing this, they should be replaced. Use original seals only.
Surface
The surface normally requires no treatment. Any damage to the coating may be remedied using a Seno
-
therm spray.
Guarantee
The guarantee does not cover damage due to insufficient maintenance!
oPeratIonal Problems
Blackened glass
The wood is too damp. Only use wood stored for at least 12 months under cover and with a moisture
level not exceeding 18% RH.
Insufficient intake of secondary air for glass pane rinse. Open sliding damper in the door.
Smoke in the room when opening door
By-pass damper or chimney damper can be closed. Open these.
Missing chimney draft.
Soot door leaking or dislodged. Replace or refit.
Never open the door when there are still flames on the wood.
Uncontrollable combustion
Faulty seal in door or ash pan. Fit new seal.
Check that the automatic air flow regulation system works properly: Check for leaks.
Briefly shut both regulating rods and the sliding damper. If this does not dampen the combustion, the
automatic system may have a leak.
If there is an excessive chimney draft, it may be necessary to close the right regulating rod (secondary).
Close all dampers when the stove is not in use.
If the steel plates in the combustion chamber develop scales or become deformed, this is due to excessive
heat. Stop using the stove and contact the manufacturer.
At interruptions that you cannot yourself rectify, you should contact the dealer.
declaratIon oF PerFormance
The DoP can be downloaded from our website via the following link:
HWAM Classic 7H www.hwam.com/dop/classic7h