User's Guide
485-022-V2
485-024-V2
FCC ID: RUZ-485
Temperature
Part number : MAN
-485-0030
-B
If further support or assistance is required, please contact FCS
Technical Support on 1
-800
-531
-5465
or e
-mail sales@uidconservaon.com
WARNING:
- LITHIUM BATTERIES
If baeries are exposed
- do not short circuit, re
-charge, puncture, incinerate, crush, immerse, force
discharge or expose to temperatures above the declared operang temperature range of the product.
Risk of re or explosion
. These baeries are sealed units which are not hazardous when used according
to the recommendaons of the manufacturer.
2. OPERATION
The reed switch is located on the front right of the unit. The unit will normally be
transming out of the box. If a restart is required or the unit doesn’t appear to transmit,
use the reed switch to iniate transmission. Hold a magnet to close the reed switch and
cause the rmware reset. A click from the reed switch may be heard followed by a
transmission burst.
Reed switch operaon can be veried using an RF scanner tuned to the transmission
frequency, when transming a burst or blip can be heard.
1. INSTALLATION
Opmum operang temperature should be below +50°C. We cannot guarantee the maxi-
mum life; therefore it is recommended to keep within the opmum operaon tempera-
ture range for maximum baery performance.
If monitoring hot water systems it is not advisable to mount the transmier directly on the
pipe without intervening insulaon.
For maximum transmission range the antenna of the transmier should point upward
(vercal polarizaon) and should be kept clear of obstrucons, parcularly metallic
surfaces. Mounng brackets are available, to t the cavity at the rear of the transmier.
Operang in extreme environmental condions will degrade the life
-me of the baery.