User's Guide

Encoder Transmier
485-035-V2
485-039-V2
485-036-V3
485-045-V3
FCC ID: RUZ-485
Part number : MAN
-485-0023
-C
If further support or assistance is required, please contact FCS
Technical Support on 1
-800
-531
-5465
or e
-mail support@uidconservaon.com
WARNING:
- LITHIUM BATTERIES
If baeries are exposed
- do not short circuit, re
-charge, puncture, incinerate, crush, immerse,
force discharge or expose to temperatures above the declared operang temperature range
of the product.
Risk of re or explosion
. These baeries are sealed units which are not
hazardous when used according to the recommendaons of the manufacturer.
2. CONNECTIONS
The Encoder Transmier has a 4
-core cable for connecng a water meter or Permalog+. The
table below shows the connecons for some common meters.
Encoder Transmier
Sensus
Badger
Hersey
-
Meters
Hersey/
Muller
Neptune
Permalog+
Wire
Colour
Funcon
Black
Ground
Black
Screen
Screen
Black
Green
Black
Yellow
Power/Clock
Red
Black
Black
Red
Black
Red
Red
Data
Green
Red
Red
Green
Red
Green
Blue
Not used
ENCODER TRANSMITTER QUICK START GUIDE
This guide covers only the most basic operaons including connecons and commissioning.
1. INTRODUCTION
The Encoder Transmier can read the data and idencaon informaon from water meters
using the Sensus or Neptune protocols, or from a Permalog+ leak detector.
The reading interval is factory set to 1, 5, 10 or 15 minutes. Every me the data is read the
meter reading or leak informaon is transmied via the VHF radio.
Aer every 96 readings (24
hours at 15
mins) two supplementary messages are transmied
with idencaon informaon, including the meter’s serial number. These supplementary
messages can also be triggered via a magnet during commissioning or servicing.

Summary of content (2 pages)