Datasheet

Page 1 of 2 HY-LINE AG
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: power@hy-line.ch
3.6 V, 2.3 Ah
High maximal discharge current
Integrated Protection Circuit for:
o Over charge protection
o Over discharge protection
o Over discharge current protection
o Short circuit protection
o Temperature protection (charge& discharge)
Specification
General
Configuration
1S1P
Nominal voltage
3.6 V
Nominal capacity
2300 mAh
Watt-hour rating
8 Wh
Standard charging
4.2 V, 1.61 A, 3 h, 25°C (Constant voltage,
constant current)
Standard discharging
2.3 A (Constant current, 3.0 V end)
Continuous allowable discharging current
<3 A
Cell
Type
Sanyo UR18650FK-2300mAh
Typical capacity
2300 mAh
Safety protection board
Cut off voltage
4.35 V
End of discharge voltage
2.3 V
Over discharge current detection
min.: 3.2 A max.: 4.9 A
Over discharge delay time
144 ms
Environmental
Operating temperature range
Standard charging 0..45°C
Standard discharging -20..60°C
Quick discharging 0..40°C
Physical
Dimensions
66 x 19 x 19 mm
Weight
0.05 kg
Connection
2 wires 10 cm
Li-Ion Battery H2B296