ELECTRICAL SPECIFICATIONS
Dedicated Circuits Required
Combination
Platinum
Combination
Gold
Combination
Silver
Air
Platinum
Air
Gold
Air
Silver
Hydro
Platinum
Hydro
Gold
Hydro
Silver
Soothing
Soak
PUMP REQUIRED
120V 20AMP With GFCI
3 2 2 1 1 1 2 1 1 1
INLINE HEATER REQUIRED
120V 20AMP GFCI
1 1 OPT 1 1 1 OPT 1
WHISPER FLO HEAT SYSTEM
120V 20AMP GFCI
2 OPT 2
TOTAL DEDICATED CIRCUITS
REQUIRED
4 3
2
(OPT 3) 3
1
(OPT 3)
1 3 2
1
(OPT 2)
1
ELECTRICAL
WARNING: ALL ELECTRICAL CONNECTIONS SHOULD BE MADE BY A LICENSED, LOCALLY
CERTIFIED ELECTRICIAN. IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL
ELECTRICAL CODES AND PROCEDURES. REFER TO SPECIFIC SPECIFICATION SHEET FOR
ELECTRICAL REQUIREMENTS.
WARNING: WHEN USING ELECTRICAL PRODUCTS, BASIC PRECAUTIONS SHOULD
ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
DANGER: RISK OF ELECTRICAL SHOCK!! This unit REQUIRES one or more dedicated circuits,
protected by a GROUND FAULT CIRCUIT INTERRUPTER (GFCI). A GFCI is not supplied, however
we do specify its use. All known code authorities require a GFCI. Rough in wiring to pump(s) and/or
heater on dedicated 120v 20-amp GFCI protected circuit(s). Please refer to specications sheet for
bath requirements.
BONDING WIRE: Grounding is required. The unit should be installed by a qualied Electrician and
grounded as specied. For built in and custom units, install a permanent access for servicing.
WARNING: Risk of electrocution-All electrical connections should be performed by a licensed
Electrician in compliance with local and national codes. In addition, a GFCI must protect all branch
circuits to the whirlpool and every electrical component must be grounded.
Run the required number of 120 volt 20 amp branch circuit(s) to a junction box within 2’ (24 inches) of
the whirlpool pump or heater. The branch circuit(s) MUST BE GFCI PROTECTED. Refer to the model
specication sheet for the specic number and size of the GFCI circuits required.
Use copper conductors only. Insure the pump is properly grounded and the pump is bonded as
required.
CAUTION: Before the use of the pump or heater, test the GFCI for proper operation. The pump
or heater should turn off when the GFCI test button is pushed. Note: the heater will only operate if the
pump is running.