Operation Manual

Table Of Contents
- 9 -
1. Specifications
1.1 Technical data hydro-pro inverter pool heat pumps
Model
Inverter 07
Inverter 10
Inverter 13
Inverter 17
Inverter 21
Item No.
7018545
7018546
7018547
7018548
7018549
* Performance at Air 27
, Water 26
, Humidity 80%
Heating capacity
kW
7-3.6
10-2.3
13-2.6
17-3.8
20-4
Power consumption
kW
1.06-0.3
1.52-0.18
1.94-0.2
2.54-0.29
2.98-0.3
C.O.P.
12-6.6
13-6.6
13-6.7
13-6.7
13-6.7
* Performance at Air 15
, Water 26
, Humidity 70%
Heating capacity
kW
5.1-2.5
7.1-1.9
9.6-2
11.5-3
14-3
Power consumption
kW
1-0.38
1.4-0.25
1.84-0.27
2.2-0.37
2.7-0.37
C.O.P.
6.5-5.1
7.5-5.1
7.5-5.2
8.2-5.2
8.2-5.1
* Performance at Air 35
, Water 27
, Humidity 40%
Cooling capacity
kW
3.6-1.68
5.0-1.21
6.6-1.4
8.3-2.0
9.7-2.06
Power consumption
kW
1.25-0.44
1.75-0.28
2.3-0.31
2.88-0.42
3.68-0.4
E.E.R.
3.78-2.88
4.25-2.88
4.49-2.88
4.73-2.88
5.11-2.64
Rated water flux
m
3
/h
2.50
3.00
4.00
5.00
6.00
Fan power input
w
5-20
8-40
8-40
10-50
10-50
Voltage
220~240V/50Hz/1PH
Maximum Current
A
4.43
6.65
8.57
11.31
12.98
Minimum Fuse
Current
A
12
18
24
31
36
Water in-out
connection
mm
50
Fan quantity
1
1
1
1
1
Ventilation type
Horizontal
Horizontal
Horizontal
Horizontal
Horizontal
Compressor brand
GMCC
GMCC
MITSUBISHI
MITSUBISHI
MITSUBISHI
Noise level at 1m
dB(A)
40-50
40-52
40-54
41-56
41-56
Net dimension
mm
1008*380*577
1050*440*709
1050*450*870
Net weight
Kg
54
68
78
98
108
Packing dimension
mm
1095*430*705
1130*470*850
1140*480*1010
Gross Weight
Kg
66
73
83
113
123
* Above data are subjects to modification without notice.