- 23 -
Hold and for 5 seconds to lock/Unlock the display.
Water temperature setting :
Press
or
to set the water temperature directly.
Parameter checking :
Press first, then press to check the “ User parameter from d0 to d11
Code
Condition
Scope
Remark
d0
IPM mould temperature
0-120℃
Real testing value
d1
Inlet water temp.
-9℃~99℃
Real testing value
d2
Outlet water temp.
-9℃~99℃
Real testing value
d3
Ambient temp.
-30
℃~
70
℃
Real testing value
d4
Return gas temp.
-30℃~70℃
Real testing value
d5
Piping temp.
-30℃~70℃
Real testing value
d6
Gas exhaust temperature
0℃~C5℃ (125℃)
Real testing value
d7
Step of EEV
0
~
99
N*5
d8
Compressor running frequency
0~99Hz
Real testing value
d9
Compressor current
0~30A
Real testing value
d10
Current fan speed
0-1200 (rpm)
Real testing value
d11
Error code for last time
All error code
Press first, then press to check/adjust the “ User parameter from P1 to P7
Code
Name
Scope
Default
Remard
P1
Working mode
0-1
1
1 Heating mode
,
0 cooling mode
P2
Timer on/off
0-1
0
1 Timer on/off is under function
,
0 Timer on/off is out of
function (The setting of P4 and P5 won’t work)
P3
Water pump
0-1
0
1 Always running
,
0 Depends on the running of compressor
P4
Current time
HH:MM
00:00
0-23:0-59
P5
Timer on
HH:MM
00:00
0-23:0-59
P6
Timer off
HH:MM
00:00
0-23:0-59
P7
Inlet water temp.
correction
-9~9
0
Default setting: 0
6.2.4 System reset function
Press and in 10s, the system will reset and display “0000” on the controller.
6.2.5