Installation Instructions
Installation Manual
Page
23
Size the gas pipe appropriately to supply the necessary volume of gas
required for the micro-boiler using ANSI Z223.1/NFPA 54 in the USA or CAN/
CSA B149.1 in Canada or local codes. Otherwise, ow capabilities and
output temperatures will be limited.
This unit is not equipped with a regulator. A gas regulator is required for all
gas appliance installations.
You should always check and follow local codes and regulations. THIS IS
ONLY TO BE INSTALLED BY A LICENSED PROFESSIONAL.
-Gas Connections-
1. Install a manual gas shutoff valve, drip leg, exible gas line and regulator between the micro-boiler
and the gas supply line as pictured. The gas supply line shall be checked for leaks using code
approved methods.
2. When the gas connections are completed, it is necessary to perform a gas leak test either by
applying soapy water to all gas ttings and observing for bubbles or by using a gas leak detection
device.
• The micro-boiler and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2 psi
(3.5 kPa).
• The micro-boiler must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
3. Always purge the gas line of any debris and/or water before connecting to the gas inlet.
NOTICE
Installation - Gas