Installation Instructions
Installation Manual
Page
29
Installation
Check the elevation where your micro-boiler is installed. Set DIPswitches shown in the tables below
depending on the altitude.
Altitude
0 to 2,000 ft.
(DEFAULT)
2,000 to
3,000 ft.
3,000 to
5,000 ft.
5,000 to
7,500 ft.
7,500 to
10,100 ft.
DIPswitches
No. 3 : OFF
No. 4 : OFF
No. 5 : OFF
No. 3 : OFF
No. 4 : ON
No. 5 : OFF
No. 3 : OFF
No. 4 : OFF
No. 5 : ON
No. 3 : OFF
No. 4 : ON
No. 5 : ON
No. 3 : ON
No. 4 : ON
No. 5 : ON
1 2 3 4 5 6 7 8 9
10
OFF
ON
1 2 3 4 5 6 7 8 9
10
OFF
ON
Bank of DIPswitches
Computer board
NOTE: The dark squares indicate the direction the DIPswitches should be set to.
Only adjust the necessary switches.
1 2 3 4 5 6 7 8 9
10
OFF
ON
1 2 3 4 5 6 7 8 9
10
OFF
ON
1 2 3 4 5 6 7 8 9
10
OFF
ON
-HIGH-ALTITUDE INSTALLATIONS-