Installation Instructions
Installation Manual
Page
4
Specications
SPECIFICATIONS
* 40 psi (0.27 MPa) or above is recommended for maximum ow.
** The manifold pressure is the factory setting and should not need adjustment.
Note:
Check the rating plate to ensure this product matches your specications.
In accordance with ANSI Z21.10.3, CO emission does not exceed 400 PPM for normal input.
The manufacturer reserves the right to discontinue, or change at any time, specications or designs
without notice and without incurring obligation.
Hydro Smart Gas Condensing Micro-Boiler
Natural Gas Input
(Operating Range)
BTU/h
Min.: 15,000
Max.: 120,000
Propane Input
(Operating Range)
BTU/h
Min.: 15,000
Max.: 120,000
Gas Connection 1/2" NPT
Water Connection 3/4" NPT
Water Pressure*
psi
(MPa)
15 - 150 (0.1 - 1.0)
Natural gas
Inlet Pressure
inch W.C.
(kPa)
Min. 5.0 (1.2)
Max. 10.5 (2.6)
Propane
Inlet Pressure
inch W.C.
(kPa)
Min. 8.0 (2.0)
Max. 14.0 (3.5)
Manifold
Pressure
**
Natural
Gas
inch W.C.
(Pa)
3.30
(820)
2.00
(500)
Propane
inch W.C.
(Pa)
3.00
(750)
1.60
(400)
Weight lbs. (kg) 50 (22.5) 50 (22.5)
Dimension
inch
H 21-3/4 x W 14 x D 9-1/4
H 552 x W 352 x D 236
mm
Ignition Electric Ignition
Electric
Supply VAC / Hz 120 / 60
Consumption
Operation W / A 53.9 / 0.7
Standby W / A 3.2 / 0.05
Freeze-
Protection
W / A 223.9 / 1.94