Troubleshooting
Display
Green
LED
Malfunction
Description
Diagnosis
391
Two
Times
Air-Fuel ratio rad
failure
Check for connection/breakage of wires (Part #708)
and/or soot on the AFR rod (Part #108).
510
Six Times
Abnormal main gas
solenoid valve
Check for connection/breakage of wires (Part #707)
and/or burn marks on the computer board (Part #701).
Check for signs of vent corrosion.
Check gas valve contacts and gas valve wire harness
connections for signs of rust or corrosion.
551
Six Times
Abnormal gas
solenoid valve
Check for connection/breakage of wires (Part #707)
and/or burn marks on the computer board (Part #701).
Check gas valve contacts and gas valve wire harness
connections for signs of rust or corrosion.
611
Four
Times
Fan motor fault
Check for connection/breakage of wires, dust buildup
in the fan motor (Part #103) and/or burn marks on the
computer board (Part #701).
Check for frozen/corrosion of connectors (Part #103).
701
One Time
Computer board
fault
Check for connection/breakage of wires (Part #711).
711
One Time
Gas solenoid valve
drive circuit failure
Refer to the 111 and 121 error codes.
721
Six Times
False ame
detection
Check if there is a leaking from heat exchanger (Part
#401).
751
N/A
Miscommunication
between micro-boiler
and temperature
controller
Inspect the connections between the micro-boiler and
temperature controller.
Check the power supply of the micro-boiler.
941
Five
Times
Abnormal exhaust
temperature
Check to see if the exhaust temperature is higher than
149°F (65°C).
991
Five
Times
Imperfect
combustion
Check if the gas type of the micro-boiler matches the
gas supplied to it.
Inspect the environment around the micro-boiler.
Determine how long the micro-boiler has been installed
and match DIPswitches.
Check the altitude/elevation of the area of where the
micro-boiler is installed.
Check if there is any blockage in the intake air and/or
exhaust.
If the micro-boiler is installed as a direct-vent system,
check whether there is enough distance between the
intake air terminal and the exhaust terminal.
Check if there is grease and/or dirt in the burner (Part
#101) and the fan motor (Part #103), especially if the
micro-boiler has been installed in a contaminated area.
Check the DIPswitches match gas type of the micro-
boiler.
Check the manifold pressure at Max. and Min.
Check combustion chamber tube (Part #117) to see if it
is clear and securely installed.