Installation Instructions
36
TEMPERATURE SETTINGS ON THE PCB
(WITHOUT REMOTE CONTROLLER)
There are 2 preset DIPswitches (120° F (50° C) and 140° F (60° C)) that you can select from by
changing the DIPswitch settings on the computer board without the remote controller. See the table
below. When the remote controller is in normal operation, the set temperature of the remote controller
is given priority over th set temperature of the DIPswitch settings.
• The temperature has been preset at the factory to 120° F (50° C).
• DO NOT adjust the upper bank of DIPswitches
• Turn off the power supply to the micro boiler before changing the DIPswitch settings.
NOTE: Only change the switches with dark squares. The dark squares indicate the
direction the DIPswitches should be set to.
(Lower bank of DIPswitches)
140 °F (60 °C)
120 °F (49 °C)
DEFAULT
No. 5 : OFF No. 5 : ON
ON
1 2 3 4 5 6
OFF
ON
1 22 33 44 55 66
OFF
Computer board
Upper bank of
DIPswitches
Lower bank of
DIPswitches
WARNING