Installation Instructions

38
MAINTENANCE AND SERVICE
Turn off the electrical power supply and close the manual gas shutoff valve
and the manual water control valve before servicing.
Be sure that all openings for combustion and ventilation air are not blocked.
The venting system should be checked annually for any leaks, corrosion, blockages or damage.
The burner should be checked annually for dust, lint, grease or dirt.
Keep the area around the micro boiler clear. Remove any combustible materials, gasoline or any
ammable vapors and liquids.
In accordance with all local codes and common safety practices, water discharged from the pres-
sure relief valve can cause severe burns instantly from scalding. DO NOT touch the pressure relief
valve.
If the relief valve discharges periodically, it may be due to thermal expansion in a closed water
supply system. Contact the water supplier or local plumbing inspector on how to correct this situa-
tion.
Visual check of burner ames (see below) through the burner window in the burner assembly lo-
cated at the middle of the micro boiler.
The manufacturer recommends having the unit checked once a year or as necessary by a licensed
technician. If repairs are needed, any repairs should be done by a licensed technician.
UNIT DRAINING
1. Close the manual gas shutoff valve.
2. Turn off power to the unit and wait a couple of
seconds.
Turn on again.
3. Wait 30 seconds, and then turn off power to
the unit, yet again.
4. Close the water shut off valve.
5. Have a bucket or pan to catch the water from
the unit’s drain plugs. Unscrew the two drain
plugs (large and small) to drain all the water
out of the unit.
6. Wait a few minutes to ensure all water has
completely drained from the unit.
Flame
blowing up
Red or Yellow
Gas
Water valve
valve
(Small)
Drain plug
Drain plug
(Large)