Installation Instructions

33
NORMAL OPERATION
TEMPERATURE CONTROLLER AND REMOVE CONTROLLER
The illustration below shows an example of the controllers. The exact display may differ from examples.
GENERAL
Flow rate to active micro boiler: 0.5 gallon per minute at the default set
temperature
Flow rate to keep the micro boiler running: 0.4 gallon per minute.
The controllers have an energy saving mode. Five minutes after the micro
boiler stops operating, the back-light of the controllers turn off.
The back-light of the controllers will turn back on once the micro boiler be-
gins ring again.
STAND BY LED (Orange)
"HOT" Buon
"COLD" Buon
Press the "HOT" buon or the "COLD"
buon to set the hot water temperature.
IN USE LED (Green)
The indicator is ON to show that
power is ON.
The indicator lights during combuson.
"INFO" Buon
Inlet water
Each me the buon is pressed,
the operaon mode is selected
in the sequence of the following.
temperature
Outlet water
temperature
Water
ow
Built-in controller
Display for Temperature
When the STAND BY LED is ON, the
hot water temperature will be
displayed.
"ON/OFF" Buon
Remote controller
Press this buon to
start or stop operaon.
NOTICE
When the remote controller is installed it will take priority over the built-in controller.
The controller has an energy saving mode. Five minutes aer the water heater stops
operang, the backlight of the controller turns o.
The backlight of the remote will turn back on once the water heater begins firing again.
Temperature Controller