2.22 Main Board Connections
2.OO installation (continued)
2.2O Electrical Installation
WARNING: Electrical installation and maintenance should be completed by a qualified electrician. All local and national
electrical regulations are to be observed.
CAUTION: All electrical connections (excluding the conductivity probe) are to be made either in the dish machine
control circuit panel or in a suitable, external junction box.
Where applicable, all cable entries into new equipment must be made with a water tight conduit fitting or
gland, meeting the appropriate local and national regulations.
Ensure all wiring is routed neatly and safely between appliances, as not to create any trip hazards that
could result in injury, or damage to the equipment or wiring.
2.21 Electrical Connections
Inductive Probe
(optional)
Main Power and
Machine Signals
Sensor Probe
Input
Conductivity
Probe
Tank Temp
(optional)
Rinse Temp
(optional)
Internal /
External Alarm
Output
(24 VDC)
Solid Line = Input
Dashed Line = Output
AC Mains
(100-230 VAC at 50/60 Hz)
Rinse Signal Input
(24 VDC or 24-250 VAC at 50/60Hz)
24 VDC (6W Max)
Detergent Signal Input
(24 VDC or 24-250 VAC at 50/60Hz)
Inductive
Probe
Board
Probe
Inputs
Depletion
Wand Inputs
External Output
Pump / Solenoid
Control Outputs
Orange
Green
Brown
White
Black
Power Supply
& Signal
Conditioning
Black
White
Red
- Black
+ Red
Yellow
Black
Black
Red
Red
Red
Brown
Black
Yellow
DetergentSanitizer
Red
+
Black
-
Rinse
Purple
Blue
Green
Sanitizer
Rinse
Detergent
Main Power Input
Detergent Signal
Basic Conductivity Probe
Rinse Signal
Brown - Line / Hot (
100-230V AC at 50/60 Hz)
Yellow - Live or DC+ (24V to 250V AC at 50-60 Hz or 24VDC)
Black - Conductivity Circuit Wire 1
Red- Live or DC + (24V to 250V AC at 50-60 Hz or 24VDC)
Blue - Neutral
White - Neutral or DC -
Red -
Conductivity Circuit Wire 2
Black - Neutral or DC-
DETERGENT RINSE AID POWER
NOTE: Two-pump system
shown, with Basic
Conductivity Probe.
-
-
Red
+
+