2.OO installation (continued)
2.27 Main Power Input Wiring
Power input to the DMx can be any voltage from 100-230
VAC at 50/60 Hz. For single phase systems, the brown
wire of the seven-wire harness is connected to the Hot
source and the blue wire is connected to the Neutral
source, as shown to the right.
With a three phase supply, the DMx is a single-phase load.
Line voltage is applied using just two wires (Brown and
Blue). Avoid interconnection to power systems that are
not ground-referenced. Choose a connection between a
line (phase) and neutral, connecting the brown wire to
the line and the blue wire to the neutral, following the
illustrations below.
2.28 Detergent Signal Wiring
Detergent signal input is optically isolated and draws no
more than 20mA.
It is a universal voltage input that accepts voltage
between 24-250VAC nominal (± 10% fluctuation), or
24VDC nominal (± 20% fluctuation).
Typical wiring locations are dispenser detergent power
source or the wash motor contacts in the dish machine
control panel. This power source is on when the
dishwasher is running the wash pump.
Connect yellow (DC+) and white (DC-) colored wires
to detergent signal power source.
Main Power Input Wiring: Single Phase AC Power
Main Power Input Wiring: Three Phase AC Power
Detergent Signal Wiring
Line /
Hot
Live or
DC +
Neutral
Neutral
or DC -
Brown - Line / Hot
(
100-230 VAC at 50/60 Hz)
Yellow - Live or DC +
(24V to 250V AC at 50-60 Hz or 24VDC)
Blue - Neutral
Green - Ground
White - Neutral or DC -
NOTE: An accessible neutral is required. Connect between line and neutral ONLY.
1. 120/208 VAC WYE (includes Neutral)
Brown
Blue
2. 120/240 VAC Delta with High Leg
Brown
Blue
3. 220/380VAC or 240/415VAC WYE (includes Neutral)
Brown
Blue
2.29 Rinse Signal Wiring
Rinse signal input is optically isolated and draws no
more than 20mA.
It is a universal voltage input that accepts voltage
between 24-250VAC nominal (± 10% fluctuation), or
24VDC nominal (± 20% fluctuation).
Typical wiring locations are dispenser rinse power
source or the rinse solenoid valve circuit in the dish
machine control panel. This power source is live
whenever the dishwasher is rinsing.
Connect red (DC+) and black (DC-) colored wires to
rinse signal power source.
Rinse Signal Wiring Live or
DC +
Neutral
or DC -
Red - Live or DC +
(
24V to 250V AC at 50-60 Hz or 24VDC)
Black - Neutral or DC -